NOTE
This function can only be used in conjunction with a Flexi Soft safety controller that is
connected via EFI.
Triple
If you select the
Triple
option, you can configure field sets with three fields. These field
sets comprise one protective field and two warning fields.
Further topics
•
"Simultaneous monitoring", page 88
7.6.5
Exchange of field results via EFI
DANGER
Incorrect signal evaluation
The dangerous state may not be stopped in the event of non-compliance.
b
Note the logical values of the status information of the protective fields when
transferred to the Flexi Soft safety controller.
•
The status of an evaluated protective field is logical 1 if the protective field is clear.
•
The status is logical 0 if the protective field is interrupted.
•
The status of an unallocated protective field defaults initially to logical 1.
If you evaluate the status of the protective fields using Flexi Soft, then on the
field mode
tab first select the
Transfer unallocated fields as interrupted
option.
If you have selected the
Dual protective fields
field mode, then the
Transfer unallocated fields
as interrupted
option is selected automatically.
Further topics
•
"EFI status information and control commands", page 116
7.7
Inputs
Overview
It is possible to switch between the monitoring cases of the safety laser scanner during
operation. The following options are available for doing this:
CONFIGURATION
7
8012029/ZA20/2019-11-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | S3000 Cold Store
71
Subject to change without notice