1
2
Figure 11: Simultaneous monitoring
1
Active field set
2
Active simultaneous field set
3.2.7
Interoperability
The safety laser scanner can be integrated into an EFI system. An EFI system can com‐
prise two safety laser scanners, one sens:Control device with one or two safety laser
scanners, or one Flexi Soft safety controller with up to four safety laser scanners.
The Flexi Soft safety controller supports two EFI strings to which up to two safety laser
scanners (S3000, S300, S300 Mini, or mixed) each can be connected. They can there‐
fore be used to implement applications with up to four safety laser scanners.
When using a Flexi Soft safety controller with a S3000 in dual field mode, two protec‐
tive fields and two warning fields can be monitored simultaneously. In dual protective
field mode, four protective fields can be monitored simultaneously. Up to eight protec‐
tive fields and up to eight warning fields, or up to 16 protective fields can therefore be
monitored simultaneously in one application.
PRODUCT DESCRIPTION
3
8012029/ZA20/2019-11-14 | SICK
O P E R A T I N G I N S T R U C T I O N S | S3000 Cold Store
23
Subject to change without notice