Category
Mode
LED1
LED2
Description
System sta‐
tus
Operation
Sensor ready for operation/current output
selected
Sensor ready for operation/voltage output
selected
IO-Link
IO-Link connection active
Error
Sensor not ready for operation/LED flashing at
4 Hz
Analog out‐
put
Voltage out‐
put
Analog voltage output active
Current out‐
put
Analog current output active
Digital
switching
output
HIGH
Switching output signal level
/switching signal present
Overload
Overload at digital switching output
Magnet field In measuring
range
Magnet field registered in measuring range
Outside
measuring
range
= lights up,
= flashes,
= LED off
8.3
General notes on operation
8.3.1
Analog operation
NOTE
If the sensor is carrying out cyclic IO-Link communication, the analog output is deacti‐
vated.
If the sensor is being operated with an analog interface, the position values are output
as analog values in the 0 ... 10 V or 4 ... 20 mA range.
This output can be inverted so that analog values of 10 ... 0 V and 20 ... 4 mA are
output.
NOTE
Following initialization, the magnet is deemed to be outside the measuring range until
the first valid measured value has been identified.
8.3.2
Digital operation
NOTE
In each switching mode, all the following conditions must be adhered to:
•
SP1 + hysteresis < working range
•
SP2 + hysteresis < working range
•
SP1 - hysteresis > 0
•
SP2 - hysteresis > 0
OPERATION
8
8019721.1FIH/2022-06-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | MPS-C
19