2 SPECIFICATIONS
2.3 Power Supply Specifications
29
2
2.3
Power Supply Specifications
Power supply specifications of an FX5-SF-MU4T5
*1 PELV (protective extra low voltage) and SELV (safety extra low voltage) are circuits that are protected by voltage limit or insulation.
*2 The current of the power supply that powers the module must be limited to a maximum of 6 A, either through the power supply itself or a
fuse.
*3 The maximum current supplied from the external power supply when using all output terminals in the maximum configuration that can be
configured (attaching FX5-SF-MU4T5 (one module) and FX5-SF-8DI4 (two modules)).
Power supply specifications of an FX5-SF-8DI4
Item
Specification
Internal power supply
5 VDC 200 mA, 24 VDC 5 mA
External power supply
24 VDC (+20%, -15%) 125 mA
Power supply voltage circuit system
PELV or SELV
Rated input current
5.2 A
Item
Specification
Internal power supply
24 VDC (+20%, -15%) 125 mA