OPERATION
7
91
8020065-ZLP4/2017-08-10|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | Master Data Analyzer
7.7
Performing mobile measurements
Using the WLAN module, which is available as an accessory, enables you to take
measurements regardless of the measurement location.
The only requirement: The WLAN module must be able to reach the WLAN access point
from the measurement location.
Measurements are performed as described in chapter
WARNING
Risk of injury when transporting the MDA to the place of use
The measurement gantry may accidentally be damaged when the MDA is transported on
a sliding table. Hands may be crushed between the measurement frame and the side
recesses in the housing.
Measures
▸
Use cable ties to secure the handles of the measurement gantry so that it does not
move accidentally during transport.
As the operating mode without bar code scanning does not temporarily store
measurement results, you must make sure that the data have been transmitted before
starting the next measurement.
7.8
Using the sliding table with rechargeable battery
If you are using the sliding table with the rechargeable battery which is available as an
accessory, you do not need an external voltage supply.
The built-in rechargeable battery has an operating life of around 10 hours.
The battery then has to be recharged. The Master Data Analyzer can be used during the
charging process.
Note