Operating Instructions
LMS500 Product Family
Product description
8013796/UL20/2010-09-27
© SICK AG · Division Auto Ident · Germany · Subject to change without notice
15
Chapter
3
3
Product description
This chapter provides information on the special features and properties of the LMS laser
measurement system. It describes the construction and the operating principle of the
device, in particular the different operating modes.
Please read this chapter before mounting, installing and commissioning the device.
3.1
Delivery
The LMS delivery includes the following components:
Section 10.3 “Ordering information” on page 95
provides an overview of the systems
available and the accessories available.
3.1.1
Contents of the CD-ROM
•
SOPAS ET configuration software
•
operating instructions “LMS500/511 Laser measurement system” in German and
English as PDF
•
freely available software “Adobe
®
Reader™”
The latest versions of the publications and programs included on the CD
F
ROM are also
available for download at www.sick.com.
3.2
Device variants
The LMS comprises four components:
•
the housing
•
the sensor head with the opto-electronic acquisition system
•
the application module, this defines the functionality of the LMS
•
the system plug with the configuration memory (the system plug contains all electrical
connections)
Quantity
Components
Comment
1
An LMS laser measurement system
LMS500-10000, LMS511-20100,
LMS511-10100, depending on order
1
Device instructions with electrical circuit
diagram for getting started
Is included in the LMS packaging
1
CD
F
ROM “Manuals & Software Auto Ident” Contents see
Tab. 3:
Delivery
Type
Special features
Range
Heating
Enclosure rating
LMS500-10000
Indoor variant
max. 65 m
26 m @ 10%
1)
1)
object remission
Without
IP 65
LMS511-10100
Outdoor variant
max. 65 m
26 m @ 10%
With
IP 67
LMS511-20100
Outdoor variant
max. 65 m
40 m @ 10%
With
IP 67
Tab. 4:
Device variants
Содержание LMS500-20000 PRO Indoor
Страница 1: ... ...