Operating Instructions
LMS500 Product Family
For your safety
8013796/UL20/2010-09-27
© SICK AG · Division Auto Ident · Germany · Subject to change without notice
13
Chapter
2
2.3.2
Laser radiation from the laser measurement system
Laser radiation!
The LMS corresponds to laser class 1 (eye safe) as per EN 60825-1 (for publication date
see laser warning label on the device). Complies with 21 CFR 1040.10 with the exception
of the deviations as per Laser Notice No. 50, June 2007. The laser beam cannot be seen
with the human eye.
•
Incorrect usage can result in hazardous exposure to laser radiation.
Do not open the housing (opening the housing will not switch off the laser).
Pay attention to the laser safety regulations as per IEC 60825
F
1 (latest version).
Important
No maintenance is necessary to ensure compliance with laser class 1.
Laser output aperture
The laser output aperture is the window of the front screen on the LMS.
Fig. 1:
Laser output aperture of the LMS
Laser power
The laser operates at a wavelength = 905 nm (invisible infrared light). The radiation
emitted in normal operation is not harmful to the eyes and human skin.
Laser warning label
The laser warning is on the LMS on the right side of the housing.
Window of the front