ã
Detection area
e
Measuring range
10.4
Performance
Scan/frame rate
55000 … 165000 measuring points/second
Response time
7 ms
Systematic error
± 60 mm
Temperature drift: Typically ± 0.5 mm/K
Statistical error
≤ 30 mm
Integrated application
Integrated field evaluation with flexible fields, data output
Number of field sets
Up to 10 fields
Simultaneous analysis
cases
Up to 10 analyses
Filters
Fog filter, particle filter, average filter, median filter, edge filter,
echo filter
1)
Depends on the object size and selected filter settings.
10.5
Interfaces
Ethernet
✓
, TCP/ IP, UDP/ IP
Function: HOST, OPC, NTP
Measured data output (distance, RSSI)
Data transmission rate: 10/100 Mbit/s
digital inputs/outputs
I/O (8 (multiport))
Output data
Contamination indication, IMU (secondary sensor data)
Optical indicators
2 LEDs
Configuration software
SOPAS ET, web server (display)
10.6
Ambient data
Object remission
2% ... > 1,000% (reflector)
Electromagnetic compati‐
bility (EMC)
EN 61000-6-2:2005
EN 61000-6-3:2007+A1:2011
Vibration resistance
EN 60068-2-6:2007
Shock resistance
EN 60068-2-27:2008
Ambient operating temper‐
ature
-30 °C … +50 °C
Storage temperature
-40 °C … +75 °C
Operating and storage air
humidity
Max 90% air humidity (non-condensing)
Ambient light immunity
80 klx
10
TECHNICAL DATA
50
O P E R A T I N G I N S T R U C T I O N S | LMS1104C-111031S01
8023051/1AZG/2021-05-10 | SICK
Subject to change without notice