Electrical installation
66
© SICK AG · Germany · All rights reserved · Subject to change without notice
8012471/ZN27/2017-06-09
Operating Instructions
LMS1xx Laser Measurement Sensors
Chapter
6
6.2
Connections of the LMS1xx
LMS12x/LMS13x/LMS14x Security and LMC12x/LMC13x VdS (object protection):
You will find information on the connections of these devices in the document ”Technical
Information (installer instructions VdS)”, part no.: 8013749, issue in English.
Please see
section 1.5 “Further information” on page 9
Depending on the variant, the LMS1xx has different connections:
6.2.1
Connections of the LMS10x
LMS1xx variant
Electrical connections
LMS10x, LMS12x, LMS173 and
LMC12x
Removable system connector with:
- PG7 cable entry
1)
on the rear side
- 2 screw type terminal blocks, 17-pole inside of the
connector
Additionally one multi-pin M12 round plug-in connection
(female connector)
1)
,
LMS11x, LMS13x, LMS14x, LMS15x,
LMS182 and LMC13x
Four multi-pin M12 round plug-in connections (female
connectors, male connectors)
All devices
Front of device: one M8 round plug-in connection (serial
AUX interface)
2)
1) You can move the PG7 cable entry and the round plug-in connection (both independent from each other) from
the rear to the underside of the system connector (see
2) This interface is only used for configuration and is not allowed to be permanently connected
Tab. 18:
Overview about electrical connections of LMS1xx
Fig. 44:
LMS10x: Position of the electrical connections
System connector
with terminal blocks
Cable entry
“AUX” connection
(behind cover)
“Ethernet”