Chapter
5
ONLINE HELP SOPAS
LECTOR®620
62
©
SICK AG · Germany · All rights reserved · Subject to change without notice
8013778/Y269/2013-11-27
Parameters
5.7.11
Code 128 family
parameter is activated, decoding is activated for the
and
active code types. This requires the
code type to be deactivated. The
configuration tab for the corresponding code types can be seen and opened in SOPAS ET.
As only activated code types are processed, you can increase the processing speed by
deactivating the code types that are not being used.
5.7.11.1
General
Reading processes such as the number of necessary multireads, regulations for dealing
with the start and stop characters, or check digit tests are configured under the
group.
5.7.11.1.1
Code 128
parameter is activated, decoding starts for the relevant code type. This re-
As only activated code types are processed, the processing speed can be increased by
specifically activating/deactivating the necessary code types.
• Code name:
(4-value)
• Character set: alphanumeric (ASCII) with three switchable character sets and one check
digit
Character set A: Digits, upper-case letters, special characters, and ASCII control characters
Character set B: Digits, upper-case and lower-case letters, special characters and escape
characters
Character set C: 100 pairs of digits (00 to 99) and FNC1 special characters
• Structure: Start symbol, useful information, check digit, stop symbol (11 modules per
symbol, each with 3 bars and 3 gaps)
• Intrinsic safety: Very high (self-checking: Even number of bars, uneven number of gaps)
• Spatial requirements: Largest possible number of characters per centimeter
• Standard: ISO/IEC 15420
• Area of application: All areas, as UCC 128/EAN 128 in retail
5.7.11.1.2
EAN 128
parameter is activated, decoding is activated for the code type. (Code type
must be deactivated.)
As only activated code types are processed, you can increase the processing speed by
specifically activating/deactivating the required code types.