Switching threshold ‘’close to mark’’ via teach-in-button

NOTE

By default, the switching threshold is set in the center between the background and the

mark. In the event of intermittent error switching on the background, it may be helpful

to place the threshold close to the mark to increase stability (dotted line instead of solid

line in the figure below).

1

2

3

1

Switching output Q

2

Switching threshold

3

Internal signal received

This can be done by pressing teach-in button again > 20 ms and < 10 s after static or

dynamic teach-in. Emitted light and function LED flash 2 x. If the switching threshold is

to be reset to the center, new teach-in is required.

NOTE

Light / dark switch:
Switching output active on mark, if background is longer in the field of view during the

teach-in or vice versa.
This can be reversed if mark is longer in the field of view during the teach in process.

COMMISSIONING

18

O P E R A T I N G   I N S T R U C T I O N | KTML

8025181/09.01.2020 | SICK

Subject to change without notice

Содержание KTM-LN2218 P Series

Страница 1: ...O P E R A T I N G I N S T R U C T I O N KTML Contrast sensors...

Страница 2: ...the limits of the legal determination of Copyright Law Any modifica tion abridgment or translation of this document is prohibited without the express writ ten permission of SICK AG The trademarks stat...

Страница 3: ...Mounting the device 10 4 Operating and status indicators 12 5 Electrical installation 13 5 1 Notes on the electrical installation 13 5 2 Pin assignment of the connections 14 5 3 Connecting the supply...

Страница 4: ...11 1 Licenses 25 CONTENTS 4 O P E R A T I N G I N S T R U C T I O N KTML 8025181 09 01 2020 SICK Subject to change without notice...

Страница 5: ...which the device is integrated For information about this refer to the operating instruc tions of the specific machine 1 2 Scope These operating instructions serve to incorporate the device into a cus...

Страница 6: ...ownload there Type specific online data sheets for device variants containing technical data and dimensional drawings EU declaration of conformity for the product family Dimensional drawings and 3D CA...

Страница 7: ...with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated June 24 2007 LASER CLASS 1 KTML 250 mm version EN IEC 60825 1 2014 IEC60825 1 2007 Laser 1 Maximum pulse pow...

Страница 8: ...quirements for skilled persons and operating personnel WARNING Risk of injury due to insufficient training Improper handling of the device may result in considerable personal injury and material damag...

Страница 9: ...eration of the devices in their particular application Knowledge of the operation and control of the devices in their particular application Knowledge of the software and hardware environment in the a...

Страница 10: ...the pairs of mounting threads fixing holes provided for this purpose Shock and vibration free mounting 3 3 Mounting the device Figure 1 KTML 1 Install the sensor via the fixing hole so that the light...

Страница 11: ...1 Distance x KTM Lx22xxxx 50 mm KTM Lx55xxxx 250 mm MOUNTING 3 8025181 09 01 2020 SICK O P E R A T I N G I N S T R U C T I O N KTML 11 Subject to change without notice...

Страница 12: ...ED indicator green supply voltage active 3 Teach in button NOTE 30s Activation and deactivation hold down teach in button 30 s Emitted light and func tion display flash 3 x 4 OPERATING AND STATUS INDI...

Страница 13: ...ng on electrical systems Only switch on the supply voltage for the device when the connection tasks have been completed and the wiring has been thoroughly checked When using extension cables with open...

Страница 14: ...ge supply that is already switched on Only connect the device when the supply cable is de energized The device must be connected to a power supply unit with the following properties Supply voltage DC...

Страница 15: ...9 84 280 11 02 Sensor Figure 4 Line spot dimensions in mm inch 250 mm version Please note the differences in the sensitivity at different sensing ranges 140 120 100 80 60 40 20 20 0 79 30 1 18 40 1 5...

Страница 16: ...e second teach in process must be triggered 2 Bring background into the light spot and start teach in with teach in button 20 ms 3 s 3 s The optimum emitted light is automatically selected The switch...

Страница 17: ...h light spot min one repeat length Quit the teach in procedure by releasing the teach in button The optimum emitted light is automatically selected The switching threshold is set in the center between...

Страница 18: ...old 3 Internal signal received This can be done by pressing teach in button again 20 ms and 10 s after static or dynamic teach in Emitted light and function LED flash 2 x If the switching threshold is...

Страница 19: ...n LEDs blinking Q Emitted light blinking 5 Hz pulse via switching output Q Insufficient contrast Sensing distance exceeded Readjust sensor Clean the sensor lens Try tilting the sensor TROUBLESHOOTING...

Страница 20: ...damage Only use suitable cleaning agents Never use sharp objects for cleaning Cleaning the light emission window NOTICE Damage to the light emission window Reduced reading performance due to scratches...

Страница 21: ...re that the heat produced by the internal power loss is adequately dissi pated the housing surface must be kept clean MAINTENANCE 8 8025181 09 01 2020 SICK O P E R A T I N G I N S T R U C T I O N KTML...

Страница 22: ...to international directives batteries accumulators and electrical or electronic devices must not be disposed of in general waste The owner is obliged by law to return this devices at the end of their...

Страница 23: ...N A N A IO Link No No Switching frequency KTM Lx22xxxx 4 kHz3 KTM Lx55xxxx 1 5 kHz3 Jitter KTM Lx22xxxx 57 s KTM Lx55xxxx 122 s Max response time KTM Lx22xxxx 125 s4 KTM Lx55xxxx 333 s4 Enclosure rati...

Страница 24: ...00 2 3 0 09 18 3 0 72 305 12 01 9 7 0 38 12 0 47 1 2 4 4 3 1 Center of optical axis sender 2 Center of optical axis receiver 3 Operating and status indicators 4 M3 threaded mounting hole 10 TECHNICAL...

Страница 25: ...license This program is provided for general use without warranty of any kind This warranty dis claimer also extends to the implicit assurance of marketability or suitability of the pro gram for a par...

Страница 26: ...8080 7425 E Mail enquiry my sick com Mexico Phone 52 472 748 9451 E Mail mexico sick com Netherlands Phone 31 0 30 229 25 44 E Mail info sick nl New Zealand Phone 64 9 415 0459 0800 222 278 tollfree...

Отзывы: