Chapter
5
Operating Instructions
ICR890 High-end CCD Camera System
64
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8011325/0000/2006-10-24
Electrical installation
5.4
Performing electrical installation
Risk of injuries due to electrical current!
The MSC800 Controller is connected to the power supply (mains voltage 100 to 264 V AC/
50 to 60 Hz).
¾
Observe current safety regulations when working with electrical equipment.
¾
Make sure the equipment
has been deenergized
before performing any installation
work.
Note
To ensure secure fastening of the plugged connectors and adherence to the enclosure
rating IP 64 for the ICR890 System, the knurled nuts/coupling rings of the M12 connectors
have to be tightened and the Harting connectors for the power supply secured by means of
the fastening bows.
¾
Wire all connections provided by the client using
shielded
copper wires!
¾
Pay attention to the required wire cross sections:
– Switching inputs/outputs: At least 0.25 mm
2
(24 AWG)
– Data interfaces: At least 0.22 mm
2
(24 AWG)
¾
Lay all the cables in such a manner that persons cannot trip over them and that the
cables are protected against damage.
Recommendation
Attach suitable wire end ferrules to the open wire ends of flexible cables which are fixed to
terminal screws. However, do
not
use wire end ferrules when fixing open wire ends to
spring
terminals
, since secure contact is otherwise not ensured.
5.4.1
Connecting the power supply cable and the ICI890 Illumination control line
The system-internal connection between the ICD890 Camera and the ICI890 Illumination is
realized via two short cables (no. 2039397 and no. 6030216) included in the delivery.
¾
Plug the power supply cable no. 2039397 into the 8-pole Harting HanQ8 socket
POWER OUT of the ICD890 Camera and fix it.
Plug the other cable end onto the corresponding 8-pole Harting HanQ8 plug of the
ICI890 Illumination and fix it.
¾
Plug the control line no. 6030216 into the 8-pole M12 socket ILLUMINATION of the
ICD890 Camera and fix it.
Plug the other cable end onto the corresponding 8-pole M12 plug of the ICI890
Illumination and fix it.
5.4.2
Power supply of the ICR890 System
Power supply requirements
A supply voltage of 24 V DC ± 10 % is required for the operation of the ICR890 System
(functional extra-low voltage according to standard IEC 364-4-41 (VDE 0100 (Part 410)).
This voltage is generated by the power supply in the MSC800 as standard. The typical power
consumption per ICD890 Camera and ICI890 Illumination amounts to a total of 425 W.
Note
The wire cross section for the power supply of the ICR890 System has to be at least 3 mm
2
(12 AWG). To ensure protection against short circuit/overload of the supply line, the cable
has to be protected according to the wire cross sections used. The valid standards must be
observed.