Operating Instructions
Chapter
4
ICR890
Installation
8011325/0000/2006-10-24
©
SICK AG · Division Auto Ident · Germany · All rights reserved
45
4
Installation
4.1
Overview of installation sequence
This chapter describes the installation sequence for components of the ICR890 System and
external components.
Note
Prerequisite for the installation of components is a suitable
installation frame
at the
installation location. The installation frame has to be assembled according to the
specifications of a
project-specific dimensional sheet
.
The typical installation sequence is displayed below:
•
Installation of the photoelectric reflex switch
•
Installation and alignment of the deflection mirror
•
Installation and alignment of the ICI890 Illumination and the ICD890 Camera
•
Installation of the MSC800 Controller
•
Installation of the MLG Light Grid or the VMS4xx/5xx
•
Installation of the incremental encoder
Note
Do not open the ICD890 Camera or the ICI890 Illumination. If the devices are opened,
the manufacturer's warranty shall not apply.
4.2
Installation preparations
4.2.1
Layout the components which are to be installed
The following components of the ICR890 System have to be placed ready for installation:
•
Deflection mirror
with protective film
•
ICI890 Illumination
with protective caps
•
ICD890 Camera
with yellow and black protective caps
Chapter 4.4 Installing external components, page 51
4.2.2
Layout accessories
The following accessories are included and have to be placed ready for installation:
•
2 x 180° bracket for the deflection mirror incl.
– 2 clamping screws for each bracket
– 2 bolts for each bracket with 2 slot nuts for attachment to the installation frame
•
4 fastening screws for the deflection mirror
•
2 x 180° bracket for the ICI890 Illumination incl.
– 2 clamping screws for each bracket
– 2 bolts for each bracket with 2 slot nuts for attachment to the installation frame
•
4 fastening screws for the ICI890 Illumination
The following tools and resources are required for installation:
•
Project-specific dimensional sheet
•
Allen key (6 mm (0.24 in)) suitable for all screws
•
Tape measure
•
Goniometer