6. Remove both protective caps from the camera.
7. Place the camera on the illumination and screw it to the illumination using the four
hexagon socket screws (centering pin with thread).
8. Loosen the clamping screws at the 180° brackets, horizontally rotate the illumination
and retighten the clamping screws.
4.4
Installing external components
4.4.1
External sensors for triggering
The reading pulse sensor (photoelectric reflex switch) is attached to the right-hand edge of
the conveyor system according to the specifications in the project-specific dimensional
sheet. The position of the photoelectric reflex switch is the
reference point
for the position
of the other components (see
). The photoelectric reflex switch has to be
aligned as vertically as possible in the direction of transport.
¾
Install the photoelectric reflex switch onto the conveyor system.
Abb. 4-8:
Removeable protective camera caps
Protective caps
Abb. 4-9:
Position of the external components
MLG Light Grid
Photoelectric
reflex switch
MSC800
Controller
Incremental encoder
Direction of transport