3
Mounting
WARNING
Mounting is only allowed to be performed by qualified safety personnel.
b
Observe EN ISO 14119 for using interlocking devices associated with physical
guards.
Fit the safety switches such that
•
it is difficult for operators to access when the protective device is open,
•
it is possible to inspect and replace the safety switches.
NOTICE
Safety switches and actuators must not be used as a mechanical stop.
2 x M5 C SK
3 x M20
2 x M5
2 x M5
1,4 N m
12.39 lb in
IP67
Figure 1: Monting safety switch
2mm
Figure 2: Mounting
b
Mount the safety switch positively.
b
Tighten the safety switch using 2 × M5 screws to 1.4 Nm (
b
To fix the safety switch, fit additional dowel pins.
b
Connect the actuator to the protective device durably and non-detatchably, e.g.
using one-way bolts or by riveting or welding.
b
Fit an additional stop for moving parts of the guard (
b
Insert the actuator into the actuating head.
MOUNTING
3
8027215/1CY3/2022-10-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | i17S
7
Subject to change without notice