Technical Information
Chapter
6
HC8X Heat Control
Temporary Shutdown
8010043
©
SICK AG · All rights reserved
6-35
6
Temporary Shutdown
6.1
Switching off the HC8X
Uncontrolled process due to status changes of the heaters!
Inform the equipment operator before switching off the heat control.
Note
All parameters and configuration data are maintained when the HC8X is switched off.
1.
Switch off the supply voltage of the power electronics (terminal strip X9) and secure it
against switching on again.
2.
Switch off the supply voltage of the control electronics and pull the plug from the mains
socket.
6.2
Switching the HC8X on Again
1.
Insert the plug in the mains socket of the HC8X and switch on the supply voltage of the
control electronics.
1.
Switch on the supply voltage of the power electronics (terminal strip X9).
The HC8X starts operation with the parameter set which was
last permanently saved
.