LED indicator/fault pattern
Cause
Measures
Yellow LED flashes; if Health is
present then take note of the
corresponding output signal; if
Alarm is present then take note
of the corresponding output
signal
Sensor is still ready for opera‐
tion, but the operating condi‐
tions are not ideal/addition‐
ally with health output: power
supply interrupted
Check the operating condi‐
tions: Fully align the beam of
light (light spot) with the
object / Clean the optical sur‐
faces / Check sensing range
and adjust if necessary, see
figures in
/ With
health output: Check the volt‐
age supply, check all electrical
connections (cables and plug
connections).
Yellow LED lights up, no object
in the path of the beam
Excessive background remis‐
sion
Check changes to the back‐
ground. Reduce the sensitivity
of the sensor or use sensors
with background suppression
Object is in the path of the
beam, yellow LED does not
light up
Sensitivity is set too low or dis‐
tance between the sensor and
the object is too long
Increase the sensing range,
take note of the distance
between the sensor and the
background, see Figure
Object is in the path of the
beam, yellow LED does not
light up
Remission capability of the
object is insufficient
Increase the sensing range,
take note of the distance
between the sensor and the
background, see Figure
9
Disassembly and disposal
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
•
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
•
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
•
WEEE:
This symbol on the product, its package or in this document, indi‐
cates that a product is subject to these regulations.
10
Maintenance
SICK sensors are maintenance-free.
We recommend doing the following regularly:
•
Clean the external lens surfaces
•
Check the screw connections and plug-in connections
No modifications may be made to devices.
DISASSEMBLY AND DISPOSAL
9
8017851.16K9 | SICK
Subject to change without notice
19
Содержание H18 - SureSense
Страница 1: ...O P E R A T I N G I N S T R U C T I O N HTE18 Hybrid photoelectric sensors...
Страница 2: ...O P E R A T I N G I N S T R U C T I O N HTE18 Hybrid photoelectric sensors de en es fr it ja pt ru zh...
Страница 24: ...B E T R I E B S A N L E I T U N G HTE18 Hybrid Lichtschranken de en es fr it ja pt ru zh...
Страница 47: ...N O T I C E D I N S T R U C T I O N HTE18 Capteurs photo lectriques hybrides de en es fr it ja pt ru zh...
Страница 70: ...M A N U A L D E I N S T R U E S HTE18 Barreiras de luz h bridas de en es fr it ja pt ru zh...
Страница 92: ...I S T R U Z I O N I P E R L U S O HTE18 Sensori fotoelettrici ibridi de en es fr it ja pt ru zh...
Страница 115: ...I N S T R U C C I O N E S D E U S O HTE18 Fotoc lulas h bridas de en es fr it ja pt ru zh...
Страница 137: ...HTE18 de en es fr it ja pt ru zh...
Страница 158: ...HTE18 de en es fr it ja pt ru zh...
Страница 175: ...LED LED 84 LED BGS LED 87 173 LED 87 173 86 WEEE 87 SICK 86 8017851 16K9 SICK Subject to change without notice 175...
Страница 180: ...HTE18 de en es fr it ja pt ru zh...
Страница 197: ...99 C Health Health Health 95 98 195 98 195 97 8017851 16K9 SICK Subject to change without notice 197...