Specification
7.1
Technical data
1)
: The accuracy depends on calibration, installation conditions, flow profile, temperature and length of the
measuring distance
2)
: For operation with standard configuration (factory setting)
Measured value recording
Measured variables
Flow velocity, air temperature
Measuring range
–20 ... +20 m/s; infinitely variable; higher on request
Typical accuracy
1)
±
0.1 m/s
Response time
1 ... 300 s; freely selectable
Displays
LC display
For measured variables, warning and malfunction messages
LED
Voltage supply OK, malfunction, maintenance request
Installation
Measuring distance
Transducer - transducer
FLSE200-M and FLSE200-HM
5 ... 25 m
FLSE200-H
5 ... 40 m
Installation angle
Up to 10 m measuring distance 45
°
, for longer measuring distances 60
°
Air temperature
-40 ... +60
°C
Moisture
< 100%
Total cable length between
FLSE200 and MCU.
Max. 1000 m
2)
Output signals
Analog output
0/2/4 ... 22 mA, max. load 750
; resolution 0.01 mA
further analog outputs with I/O modules (option)
Digital outputs
5 potential-free outputs (NC contacts) for status signals operation/fault, maintenance, control
cycle, maintenance requirement, limit value; contact load 48 V, 1 A;
further relay outputs with I/O modules (option)
Input signals
Analog input
2 inputs 0 ... 20 mA (standard, without electrical isolation); resolution 0.01 mA;
further analog inputs with I/O modules (option)
Digital inputs
4 potential-free contacts for connection of maintenance switch, activation of check cycle;
further digital inputs with I/O modules (option)
Communication interfaces
USB 1.1, RS 232 (on terminals) For measured value inquiry, configuration and software update via PC/laptop with operating
program
RS485
For connection of sender/receiver units
Option Interface module
Optional PROFIBUS (RS485), MODBUS (RS485, Ethernet), COLA-B (Ethernet)
Power supply
Operating voltage
90 ... 250 V AC; 50/60 Hz
Power consumption
Approx. 20 W
Ambient conditions
Temperature range
-40 ... +60 °C
Storage temperature
-40 ... +70
°
C
Protection class
FLSE200: IP66, MCU: IP 65
Содержание FLOWSIC200
Страница 1: ...O PERATING INSTRU CTIO NS FLOWSIC200 Flow Velocity Monitor Installation Operation Maintenance...
Страница 30: ...30 FLOWSIC200 Operating Instructions 8013271 1CJ9 V2 0 2022 01 SICK Engineering GmbH Product description...
Страница 100: ...100 FLOWSIC200 Operating Instructions 8013271 1CJ9 V2 0 2022 01 SICK Engineering GmbH Commissioning and parameterization...
Страница 104: ...104 FLOWSIC200 Operating Instructions 8013271 1CJ9 V2 0 2022 01 SICK Engineering GmbH Maintenance...
Страница 121: ...Specification FLOWSIC200 Operating Instructions 8013271 1CJ9 V2 0 2022 01 SICK Engineering GmbH 121...