FLOWSIC100 Flare · Operating Instructions · 8013344/11L2/V 2-5/2018-10 · © SICK Engineering GmbH
Assembly and Installation
Su
bj
ect
to
ch
an
ge
with
ou
t n
otic
e
3.2
Preparation work
3.2.1
General notes
Check that the shipment contains all components ordered.
Check the components for possible transport damages. Pay particular attention to
transducer surfaces, sealing surfaces on the flanges and, if delivered, the interior of the
meter body (spool piece).
Immediately document and reported damages to the manufacturer.
Fig. 32
Main type plate on sender/receiver units
NOTICE:
To guarantee safe and reliable operation of the measuring equipment, make
sure that the actual site conditions match the information provided on the
labels on sender/receiver units and control unit (
Serial No.:
Part No.:
FLSE100 -
00
12
01
02
FLSE100-EXS
11
11
13
13
II 1/2 G Ex d [ia Ga] T Ga/Gb
TÜV 09 ATEX
Ga/Gb
554975
Ex d [ia] T
IECEx TUN 09.0015
Power supply:
15 ... 28 V DC, 50 mA
°C T
°C
amb
°C T
°C
GAS
09
08
07
06
05
04
03
P
@50°C bar
max
P
@ °C bar
max
Flange size
06
IP 65/67
SICK Engineering GmbH, Bergener
Ring 27, D-01458 Ottendorf-Okrilla
Read Operation Instructions
Example device type FLSE100-EXS ATEX zone 1/IECEx
Example device type FLSE100-EXS CSA Cl
I
, Div1 Group D
Variable Name
00
Device type code
01
Serial No.
02
Part No.
03
Min. ambient temperature
04
Max. ambient temperature
05
Min. gas temperature
06
Max. gas temperature
07
Max. operating pressure at 50 °C
08
Max. operating pressure at T
gas
max.
(variable 06)
09
Flange size
10
Not relevant
11
Ignition group
12
Bar code
13
Temperature class
Variable Name
00
Device type code
01
Serial No.
02
Part No.
03
Min. ambient temperature
04
Max. ambient temperature
05
Min. gas temperature
06
Max. gas temperature
07
Max. operating pressure at 50 °C
08
Max. operating pressure at T
gas
max.
(variable 06)
09
Flange size
10
Not relevant
11
Not relevant
12
Bar code