4.
In the login dialog, select the required logic access level, enter the password, and
click on
Log in
.
5.
Click on
OK
.
Logout
1.
In the
Configuration
main navigation menu, click on
Hardware configuration
under
Navigation
.
2.
Right-click on the main module and select the
Change access for logic pages
com‐
mand from the context menu.
3.
In the
Current logic access level
area, click on
Log in
.
4.
Click on
OK
.
7.6.11.3
Setting up logic access protection for a logic page
Prerequisites
•
Logic access protection is activated
Approach
1.
Open the desired page in the
Logic editor
view.
2.
Right-click on the page and select the
Set up access protection for logic page
submenu
from the context menu, followed by the required logic access level.
3.
You must log in to the required logic access level. Enter the relevant password
where applicable and click on
Log in
.
Complementary information
•
Logic pages with logic access protection can be identified by a pencil icon on the
tab.
•
For users who are not logged in with the required logic access level, the pencil icon
is crossed out.
7.6.11.4
Removing the logic access protection from a logic page
Approach
1.
Open the desired page in the
Logic editor
view.
2.
Right-click on the page and select the
Remove access protection for logic page
com‐
mand from the context menu.
3.
Enter the required password where applicable and click on
Log in
.
7.6.11.5
Applying visibility protection to a logic page
Approach
1.
Open the desired page in the
Logic editor
view.
2.
Right-click on the page and select the
Protect page visibility...
submenu from the
context menu, followed by the required logic access level.
3.
Enter the relevant password where applicable and click on
Log in
.
Complementary information
•
Logic pages with visibility protection can be identified by an eye icon on the tab.
•
Users who are not logged in with the required logic access level cannot see the
content of the logic page in question or edit it. In this case, the eye icon is crossed
out.
•
The tab for a page with visibility protection always remains visible.