6.3.5
Cycles
This page shows the following values for the cycles of the encoder from the position
sensor object (
•
Number of changes in the direction of rotation (attribute ID 75h)
•
Number of clockwise starts (attribute ID 76h)
•
Number of counterclockwise starts (attribute ID 77h)
•
Limit of the number of changes of the direction of rotation (
)
•
Limit of the number of clockwise starts (
•
Limit of the number of counterclockwise starts (
6.3.6
Heartbeat
The absolute encoder supports the slave sign-of-life functionality (
).
Figure 114: Heartbeat
If the heartbeat is set to
on
, then the following symbols and parameters are displayed:
An LED symbol indicates the heartbeat:
Green
Active
Gray
Not active
NOTE
Since the website is updated every second, the change between statuses cannot be
displayed in real time.
The
Aktueller RPI in ms
column shows the RPI.
The update factor can be specified in the
Aktueller Update-Faktor (2 … 127)
field.
The
Aktueller Update-Zyklus in ms
column shows the heartbeat.
6.4
Tools
6.4.1
EDS
The EDS files for integrating the encoder into the PLC are stored in the encoder.
b
Click
Download EDS
to download the files as a RAR archive.
The RAR archive contains the EDS files for the singleturn and multiturn encoders
and their icons.
6.4.2
Ladder routine
The ladder routine is used to map the configuration data between the controller and
the web server (
). The ladder routine is stored in the
encoder.
CONFIGURATION USING THE INTEGRATED WEB SERVER
6
8014213/1EF3/2021-12-08 | SICK
O P E R A T I N G I N S T R U C T I O N S | AFS/AFM60 EtherNet/IP
103
Subject to change without notice