11
Technical data
NOTE
The relevant online data sheet for your product, including technical data, dimensional
drawing, and connection diagrams can be downloaded, saved, and printed from the
Internet:
•
Please note: This documentation may contain further technical data.
11.1
Performance
Product type
DL1000
DT1000
Measuring range
0.2 m ... 1,500 m
1
,
2
,
3
,
see "Measuring range diagrams",
page 105
0.2 m ... 460 m
1
,
4
,
5
uring range diagrams", page 105
Resolution
0.001 mm ... 100 mm, adjustable
6
Reproducibility
1 mm ... 15 mm
1
,
2
,
7
,
10
,
see "Repeatability diagrams",
page 107
1 mm ... 15 mm
1
,
5
,
7
,
10
,
see "Repeatability diagrams",
page 107
Accuracy (distance)
Typically ± 15 mm
8
,
see "Measurement accuracy diagrams",
Measurement accu‐
racy (speed)
Typically ± 10 mm/s
10
Response time
3 ms ... 384 ms
11
Measurement cycle
time
1 ms, 4 ms, 16 ms
1 ms, 4 ms, 16 ms, 64 ms,
128 ms
Max. axial traversing
speed
128 m/s (at 1 ms measurement
cycle time)
32 m/s (at 4 ms measurement
cycle time)
8 m/s (at 16 ms measurement
cycle time)
128 m/s (at 1 ms measurement
cycle time)
128 m/s (at 4 ms measurement
cycle time)
128 m/s (at 16 ms measurement
cycle time)
2 m/s (at 64 ms measurement
cycle time)
1 m/s (at 128 ms measurement
cycle time)
Max. acceleration
150 m/s
2
150 m/s
2
(at 1, 4 or 16 ms meas‐
urement cycle time)
31.3 m/s
2
(at 64 ms measure‐
ment cycle time)
7.8 m/s
2
(at 128 ms measure‐
ment cycle time)
Light sender
Measurement laser, infrared (invisible, wavelength 905 nm, max. out‐
put power ≤ 21 W, pulse length 2.5 ns)
Alignment laser, red (visible, wavelength 650 nm, max. output power
≤ 390 μW, pulse length 50 ms)
Laser class
1 (EN 60825-1, even with simultaneous operation of measurement
and alignment laser)
Complies with 21 CFR 1040.10 and 1040.11 except for tolerances
according to “Laser Notice No. 50”, dated June 24, 2007.
TECHNICAL DATA
11
8024560/1A19/2021-06-30 | SICK
O P E R A T I N G I N S T R U C T I O N S | DT1000 PROFIBUS DP and DL1000 PROFIBUS DP
103
Subject to change without notice