6.2
System connection (M12, 8-pin)
8
2
3
4
5
7
1
6
Figure 29: System connection (male connector M12, 8-pin)
Table 11: Pin assignment for the system connection (male connector, M12, 8-pin)
PIN
Wire color
1)
Active unit
1
White
In3
RES (reset pushbutton input) or override
(override input)
2
Brown
+24 V DC (voltage supply input)
3
Green
MFP3
ADO (application diagnostic output)
4
Yellow
In4
C1 muting release
5
Gray
OSSD1 (switching output 1)
6
Pink
OSSD2 (switching output 2)
7
Blue
0 V DC (voltage supply input)
8
Red
Code 1 or code 2
1)
Applies to the connecting cables recommended as accessories.
Further topics
•
"Integration in the electrical control system", page 33
6.3
Reset/override pushbutton connection (M12, 5-pin)
2
1
4
3
5
Figure 30: Reset/override pushbutton connection (female connector, M12, 5-pin)
The reset/override pushbutton connection can be used, for example, to connect the
ER12 reset pushbutton.
Table 12: Pin assignment for the reset/override pushbutton (female connector, M12, 5-pin)
PIN
Wire color
1)
Active unit
1
Brown
24 V Out (voltage supply output)
2
White
Not assigned
3
Blue
0 V Out (voltage supply output)
4
Black
In3
RES (reset pushbutton input) or override
(override input)
5
Gray
MFP3
ADO (application diagnostic output)
1)
Applies to the connecting cables recommended as accessories.
ELECTRICAL INSTALLATION
6
8024802/2020-07-17 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTem4 LT Muting A/P
57
Subject to change without notice