DIP switch 1
(row A)
DIP switch 2
(row A)
DIP switch 3
(row A)
DIP switch 4
(row A)
Function
Off
On
Off
On
Cross-muting with muting
signal 1 on system con‐
nection In4 and muting
signal 2 on extension
connection In2
On
Off
Off
Off
Exit monitoring
1)
2)
3)
On
Off
Off
On
Exit monitoring with mut‐
ing signal 1 on system
connection In4 and mut‐
ing signal 2 on extension
connection In2
1)
2)
3)
1)
Muting hold time of 4 s.
2)
Muting end by ESPE active.
3)
Muting end delay of 0.2 s.
Note on configuration
b
Check the parity after setting the DIP switches,
.
7.6
Checking the parity
The parity must be checked after setting the DIP switches. The parity specifies whether
the sum of the DIP switches set to On is even or uneven.
Parity is only calculated for the DIP switches of rows A, B and C. DIP switches 1 and 2 of
row D are not included.
The parity is set using DIP switch 4 (row C).
OFF
uncoded
code 1
code 2
ref.conf.
ON
1 2 3 4
O F F
1 2 3 4
O F F
1 2 3
4
O F F
1
O
N
2
A
B
C
D
1 2 3
4
O F F
Figure 43: DIP switch for parity on SP2 system plug
Prerequisites
•
SP2 system plug
•
Leave all DIP switches that do not have a function assigned to them in OFF state
7
CONFIGURATION
70
O P E R A T I N G I N S T R U C T I O N S | deTem4 A/P
8024782/2019-11-19 | SICK
Subject to change without notice