7
Configuration
7.1
Overview
Table 18: Functions and their configuration type
Function
Configuration type
Muting
DIP switch
Beam coding
Set to factory settings
Restart interlock
Wiring
External device monitoring (EDM)
Application diagnostic output (ADO)
The following system plugs are available for configuring via a DIP switch:
•
SP1 system plug
•
SP2 system plug
The system plugs are used on the active unit of the multiple light beam safety device.
OFF
uncoded
code 1
code 2
ref.conf.
ON
1
O
N
2
Figure 38: SP1 system plug with 2 DIP
switches
OFF
uncoded
code 1
code 2
ref.conf.
ON
1 2 3 4
O F F
1 2 3 4
O F F
1 2 3 4
O F F
1
O
N
2
A
B
C
D
Figure 39: SP2 system plug with 14 DIP
switches
Table 19: Overview of DIP switches
Row
DIP switch
Function
A
1)
1, 2
Muting,
see "Configuring muting", page 69
3
Not assigned
4
Muting,
see "Configuring muting", page 69
B
1)
1, 2, 3, 4
Not assigned
C
1)
1, 2, 3
Not assigned
4
Parity,
see "Checking the parity", page 70
CONFIGURATION
7
8024782/2019-11-19 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTem4 A/P
65