DANGER
If the safety component is integrated incorrectly, the dangerous state may be ended to
late.
b
Plan the integration of the safety component in accordance with the machine
requirements,
see "Project planning", page 15
.
2.2
Intended use
The deTem2 Core IP69K multiple light beam safety device is an electro-sensitive protec‐
tive device (ESPE) and is suitable for the following applications:
•
Single-sided access protection
•
Multi-sided access protection
The multiple light beam safety device fulfills the requirements of the IP 69K enclosure
rating.
The deTem2 Core IP69K multiple light beam safety device must only be used within the
limits of the prescribed and specified technical data and operating conditions at all
times.
Any instance of improper use, incorrect modification, or manipulation of the deTem2
Core IP69K multiple light beam safety device shall void any warranty provided by SICK
AG; furthermore, SICK AG shall not accept any responsibility or liability for any resulting
damage and consequential damage.
2.3
Improper use
The multiple light beam safety device works as an indirect protective measure and can‐
not provide protection from pieces thrown from application nor from emitted radiation.
Transparent objects are not detected.
Among others, the deTem2 Core IP69K multiple light beam safety device is
not
suitable
for the following applications:
•
Outdoors
•
Underwater
•
In explosion-hazardous areas
•
At altitudes over 3,000 m above sea level
•
In environments with increased levels of ionizing radiation
2.4
Requirements for the qualification of personnel
The protective device must be configured, installed, connected, commissioned, and ser‐
viced by qualified safety personnel only.
Project planning
For project planning, a person is considered competent when he/she has expertise and
experience in the selection and use of protective devices on machines and is familiar
with the relevant technical rules and national work safety regulations.
2
SAFETY INFORMATION
8
O P E R A T I N G I N S T R U C T I O N S | deTem2 Core IP69K
8021554/14Q7/2020-04-27 | SICK
Subject to change without notice