Minimum
Typical
Maximum
All additional wires at the system
connection and extension connection
6)
2.5 Ω
1)
Applies to the voltage range between -30 V and +30 V.
2)
According to IEC 61131-2.
3)
The specified values are the switching voltage supplied by the safety light curtain. If higher voltages are
implanted externally, the maximum value of 2.0 V can be exceeded.
4)
When active, the outputs are tested cyclically (brief LOW). When selecting the downstream controllers,
make sure that the test pulses do not result in deactivation when using the above parameters.
5)
Limit the individual conductor resistance to the specified values to ensure that the light curtain func‐
tions correctly, particularly that a cross-circuit between the outputs is safely detected. (Also observe
IEC 60204-1.)
The specified values apply to the total resistance of each wire including contact and connector resistan‐
ces.
6)
If a T-connector is used, the specified values apply to the resistance of the entire cable from the system
connection of the device to the connection in the control cabinet.
For a cascade, the specified values apply to the resistance of the entire cable from the system connec‐
tion of the last guest device to the connection in the control cabinet.
7)
The supply cable must not be used to connect other loads with the exception of the senders.
8)
If a T-connector is used and the input current is greater than 1.2
A, the conductor resistance must not
exceed 0.5
Ω.
If the device is not used in a cascade, a T-connector is not used, and no inductive OSSD loads (e.g.,
contactors) are applied, the conductor resistance must not exceed 2
Ω.
Table 53: Operating data
Minimum
Typical
Maximum
System connection
5-pin M12 male connector
8-pin M12 male connector
Extension connection
Optional, female connector, M12, 5-pin
Lengths of cable for connecting
cables and in cascades
Lengths of cable for other cables on
the extension connection
10 m
Cable material of the system of
extension connection
PUR
Ambient operating temperature
1)
2)
3)
-30 °C
+55 °C
Air humidity (non-condensing)
15%
95%
Storage temperature
-30 °C
+70 °C
Housing cross-section
31 mm × 34 mm, plus bracket,
Vibration resistance
4)
5 g, 10 Hz … 55 Hz (IEC 60068-2-6)
Shock resistance
5)
10 g, 16 ms (IEC 60068-2-27)
1)
The temperature difference between sender and receiver must not exceed 25 K.
2)
The cable belonging to the device incl. the associated connection plug must not be flexibly mounted
under –25
°C.
3)
Maximum ambient operating temperature over 1,000
m above sea level: +50
°C.
Maximum ambient operating temperature over 2,000
m above sea level: +45
°C.
4)
Test conditions per axis: 1 octave/minute, amplitude: 0.35 mm, 20 sweeps.
5)
Test conditions per axis: 1000 shocks.
13.3
Response time
NOTE
If the Smart Box Detection function is configured on the receiver with a 14 mm resolu‐
tion, a response time of 80 ms applies regardless of the protective field height and
beam coding.
13
TECHNICAL DATA
144
O P E R A T I N G I N S T R U C T I O N S | deTec4
8021645/1EB0/2022-04-28 | SICK