Serial auxiliary interface
The aux interface is configured with the parameters of the
group.
PROFIBUS DP Gateway
The PROFIBUS DP interface is configured with the parameters of the
group.
DeviceNet Gateway
The DeviceNet interface is configured with the parameters of the
2.2.5.2 Ethernet
The Ethernet interface provides the reading result for further processing by the host com-
puter.
General
The network settings of the scanner are set via the parameter of the
group. These
settings must be defined by the network administrator.
Parameter
Function
Protocol / Output format
Define the output of the auxiliary interface.
Activate heartbeats
Activate the output of a regular heartbeat.
Heartbeat interval
Enter time between two heartbeats.
Restart interval on sending
Restart interval after the output of a reading result.
Gateway
Activate PROFIBUS DP interface or DeviceNet respectively.
Parameter
Function
Use device ID as profibus
address
Activate/deactivate the scanner's device ID as profibus address.
Device ID
The device ID of the scanner is displayed.
Operating mode
Select the profibus protocol.
Parameter
Function
Use device ID as DeviceNet
address
Activate/deactivate the scanner's device ID as DeviceNet
address.
Address
Enter the device address in DeviceNet.
Operating mode
Select the DeviceNet protocol.
Baudrate
Select speed of DeviceNet interface.
Length of input-data
Enter the length of the input data.
Length of output-data
Enter the length of the output data.
Hint
The scanner has to be restarted after modification of one of this group parameters.
Parameter
Function
IP address
Enter IP address of scanner.
Subnet mask
Enter subnet mask of scanner.
Default gateway
Enter default gateway of scanner.
Speed
Select network speed.
MAC address
Enter MAC address of scanner.