Operating Instructions
Chapter
10
CLV62x Bar Code Scanner
Technical data
8011965/S345/2008-04-16
©
SICK AG · Division Auto Ident · Germany · All rights reserved
71
10
Technical data
10.1
Datasheet of CLV62x Bar Code Scanner
Type
CLV62x Bar Code Scanner
Focus
Fixed focus
Reading window
Line / Raster scanner: With front/side reading window (with angle attachment: light entrance/exit
under 105°)
Laser diode (wavelength)
Red light (
λ
= 655 nm)
MTTR of the laser diode
20,000 h
Device laser class
Class 2 in accordance with IEC 60825-1 and EN 60825-1, see warning sign on device for date of
publication
Useable aperture angle
max. 50° (front reading window)/max. 51.5° (side reading window)
Scan/decoder frequency
400 ... 1,200 Hz
Resolution
0,15 ... 1.0 mm (5.9 ... 39.5 mil) (type-dependent)
Raster height
15 mm (0.6 in) (8 lines) with 200 mm (7.9 in) reading distance (front reading window)
Bar code print contrast (PCS)
≥
60 %
Ambient light compatibility
2,000 lx (on bar code)
Number of bar codes per scan
1 ... 20 standard decoder; 1 ... 6 SMART decoder
Number of bar codes per reading
gate
1)
1 ... 50 bar codes (auto-discriminating)
Bar code types
Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved, Pharmacode
Bar code lengths
Max. 50 characters (max. 1.500 characters across all bar codes per reading gate, 500 characters
with multiplexer function (CAN))
Print ratio
2:1 ... 3:1
Number of multireads
1 ... 99
Optical indicators
6 LEDs: Ready, Result, Laser, Data, CAN, LNK TX
Acoustic display
Beeper, can be switched off, with function for result status display
Reading pulsing
Pulse sources for start: Switching inputs "Sensor 1"
2)
and/or "Sensor 2"; command; Automatic
Cycle; CAN
Pulse sources for stop: Reading pulse source, "Sensor 1", "Sensor 2", command, timer, good read,
condition
"Host" data interface
Serial: RS-232 or RS-422/485; Ethernet (port 2112),
adjustable data format (serial) and data output format
Data transfer rate
2,4 ... 115.2 kbd
Protocols
SICK standard (SOPAS-Cola-A)
Physical configurations
Stand-alone
"Aux" data interface
Serial: RS-232 (57.6 kbd; 8 data bits, no parity, 1 stop bit); Ethernet (port 2111); fixed data output
format
"Ethernet" data interface
Only for Ethernet version: 10/100 MBit/s, TCP/IP, half/full duplex
"CAN" data interface
20 kBit/s ... 1 MBit/s, SICK CAN-SENSOR network (Master, Slave, Multiplexer)
Digital switching inputs
Standard version: 2 ("Sensor 1", "Sensor 2"), 2 additional inputs via CMC600 in CDB620
Ethernet version: 1 ("Sensor 1"), 2 additional inputs via CMC600 in CDB620, optodecoupled, V
in
=
max. 32 V, reverse polarity protected, can be wired with PNP output, configurable debouncing 0
...10.000 ms
Digital switching outputs
Standard version: 2 ("Result 1", "Result 2"), 2 additional outputs via CMC600 in CDB620
Ethernet version: no output, 2 outputs via CMC600 in CDB620
PNP, I
out
= max. 100 mA, short circuit-proof, configurable impulse duration (static, 10 ... 1.000 ms)