Quick-Start
3.2
Establishing connection with the bar code scanner
¾
Communicate with the bar code scanner according to the selected data interface (RS-
232 or Ethernet) (see
chapter 7.3 Establish communication with the bar code scanner,
) and perform a scan.
TIP
To establish a connection quickly and easily via Ethernet, the SOPAS-ET configuration soft-
ware has a C
ONNECTION
W
IZARD
in the T
OOLS
menu.
3.3
Performing the reading
Fig. 3-1:
Register tab Quickstart
Perform the reading:
1. Ensure that the relevant code types are activated on the register tab.
2. Carry out a test reading with a test bar code.
To achieve this, hold an object with a bar code in front of the bar code scanner's reading
window and trigger the reading by clicking S
TART
. The default setting of the focus posi-
tion is 285 mm (11.2 in). If necessary, observe the bar code scanner's depth of fields
ranges in relation to the resolution (see
chapter 10.2 Specification diagrams,
).
The reading result is displayed in the B
ARCODE
C
ONTENT
display field.
The code reading reliability is specified in the relevant display field.
Note
With the SOPAS-ET configuration software, the Q
UICKSTART
register tab contains the most im-
portant reading parameters for configuring and performing a bar code reading:
P
ROJECT
T
REE
, CLV62
X
, Q
UICKSTART
register tab