6.4
Wiring the PROFINET interface
1.
Connect the device using the assembled cables to the left and right of the addi‐
tional device (IO devices) in the PROFINET network. Line or ring topology is possi‐
ble. If only one Ethernet connection is needed (e.g., last device in a line topology),
either the P1 or P2 connection can be used. Provide a protective cap/plug for the
unused connection (as in delivery condition).
2.
Switch on the supply voltage for the device. The device starts with a delay and
uses the default parameters set in the factory for the initialization. After a suc‐
cessful self-test, the blue LED on the device lights up to indicate the "Device
Ready" status.
CLV61x-Dx41x
Dual Port
PLC
2
/ HOST
CLV61x-Dx41x
Dual Port
CLV61x-Dx41x
Dual Port
CLV62x ...
CLV65x
Cable
3
, optional
IO Controller
(MRP manager)
PROFINET
Cable
5
Cable
4
Cable
4
Cable
4
1
PROFINET
Figure 20: Example of a PROFINET network design with a line or ring topology (CLV61x-Dx41x)
1
IO controller
2
PLC
3
Adapter cable (male connector, RJ45, 8-pin / male connector, M12, 4-pin, D-coded),
optional
4
Cable 1:1 (male connector, M12, 4-pin, D-coded / male connector, M12, 4-pin, D-coded)
5
Adapter cable (male connector, RJ45, 8-pin / male connector, M12, 4-pin, D-coded)
Cable
6
Cable
4
Cable
4
Cable
4
1
CLV61x-Dx52x
Dual Port
PLC
2
/ HOST
CLV61x-Dx52x
Dual Port
CLV61x-Dx52x
Dual Port
CLV62x ...
CLV65x
IO Controller
(MRP manager)
PROFINET
Trigger
5
Trigger
5
Trigger
5
Cable
3
, optional
PROFINET
Figure 21: Example of a PROFINET network design with a line or ring topology (CLV61x-Dx52x)
1
IO controller
2
PLC
3
Adapter cable (male connector, RJ45, 8-pin / male connector, M12, 4-pin, D-coded),
optional
4
Cable 1:1 (male connector, M12, 4-pin, D-coded / male connector, M12, 4-pin, D-coded)
5
Reading cycle trigger (local)
6
ELECTRICAL INSTALLATION
32
O P E R A T I N G I N S T R U C T I O N S | CLV61x Dual Port (PROFINET)
8017842/ZMG5/2017-06-12 | 8M_DR | SICK