Operating Instructions
Chapter
5
CLV 490 Bar Code Scanner
8 009 993/O824/20-12-2004
©
SICK AG · Division Auto Ident · Germany · All rights reserved
5-3
Electrical installation
5.2.3
Connections/cables for the CDB 420 Connection Modules
The CDB 420 Connection Module is suitable for connecting
one CLV without/with heater
to peripherals (distribution function) and the power supply. The module can be used to es-
tablish a connection to the host (point-to-point) or to integrate the device in a SICK CAN
Scanner Network. The module is available in two variants and can be operated without op-
tional modules (see below) with an operating temperature to –35
°
C (–31
°
F). For technical
data see
Chapter 10.13.2 Connection modules, Page 10-75
.
Optional modules for building-in into the CDB 420:
•
CMC 400 Connection Module Cloning for saving the parameters of the CLV externally
Because only one 15-pin D Sub HD socket respectively screw terminal strips for the power
supply via cable glands are available for connecting the CLV to the CDB 420, the number of
signals which can be connected using the terminal strips in the CDB 420 are limited.
shows the connection principle of the CDB 420.
The procedures for connecting and configuring the connection module are described in the
"CDB 420 Connection Module" Operating Instructions
(order no. 8 010 001, German/
English).
Note
Diagrams showing you how to connect the CDB 420 Connection Module are also available
in the “CLV Connect“ PC program. This software is available on the “Manuals & Software“
CD-ROM, which is included in the scope of delivery of the CLV 490. The software can also
be downloaded from the SICK home page (www.sick.de) at “Service&Support/Download-
pool“. It can be called up using a standard HTML browser (e. g. Internet Explorer
TM
).
Connecting the CLV to the CDB 420
a) CLV without heater
The following connection cables
with
connector cover for the CLV can be used:
No. 2 027 046 (3 m (3.84 ft)) or no. 2 030 023 (3 m (3.84 ft)).
The cables can be extended to 10 m (32.8 ft) (terminal interface: RS 232!).
Fig. 5-1:
Block diagram: Connection of the CLV 490 to the CDB 420 connection module
“Aux”
“Result 1 ... 2”
“IN 0”
“IN 0”
“Result 1 ... 2”
CDB 420
connection module
CLV 490
Photoelectric
switch
Reading pulse
Photoelectric
switch
Focal position
Trigger One-Shot
Conveyor increment
End of reading
interval
– – Cable if required (if necessary)
18 to 30 V DC
HOST/PLC
CAN bus
PC
PLC
AUX