Electrical installation
5
Electrical installation
5.1
Installation sequence
•
Connect the CLV to a CDB 420 or CDM 490 Connection Module, or using a customer-
specific wiring configuration
•
Connect the data and function interfaces of the CLV in the module
•
Connect the PC to the Connection Module (at the terminal interface on the CLV)
•
Connect the power supply to the Connection Module
5.1.1
SICK Connection Modules (overview)
For technical data on the modules see
Chapter 10.13.2 Connection modules, Page 10-75
.
5.2
Electrical connections and cables
The electrical connections on the CLV consist of two 15-pin D Sub HD connections on the
housing, one plug, and one socket.
These connections are used to route the following interfaces:
•
Three data serial interfaces (host interface, CAN interface 1 and 2, terminal interface)
•
Six switching inputs (external reading pulse and multifunctional inputs)
•
Four switching outputs (for result status function, for connecting to a PLC for example)
•
Power supply
5.2.1
Wire cross-sections
CLV without heater:
¾
All connections must be wired with copper cables with a minimum wire diameter of
0.15 mm
2
(approx. 26 AWG)!
CLV Type
Temperature
range
Connection
module
Purpose
see
chapter
CLV
without
heater 0
to
+40
°
C
(+32 to +104
°
F)
CDB 420-001
CDB 420-101
– Connecting
one
CLV
– 1 x 15-pin D Sub HD socket, 4 x cable gland
(CDB 420-101: 2 x cable gland, 2 x M12 plug
connection (1 x plug, 1 x socket))
– Operating voltage 18 to 30 V DC
– Enclosure rating max. IP 65
CDM 490-0001
– Connecting
one
CLV
– 1 x 15-pin D Sub HD plug, 1 x socket,
6 x cable gland
– Operating voltage 18 to 30 V DC
– Enclosure rating max. IP 65
CLV
with
heater
–35 to +35
°
C
(–31 to +95
°
F)
CDM 490-0001
– Connecting
one
CLV
– 1 x 15-pin D Sub HD plug, 1 x socket,
6 x cable gland
– Operating voltage 24 V DC +20 %/–10 %
– Enclosure rating max. IP 65 (with connector cover)
Table 5-1: Connection Modules for the CLV