![SICK CLV 490 Series Скачать руководство пользователя страница 230](http://html.mh-extra.com/html/sick/clv-490-series/clv-490-series_operating-instructions-manual_1264226230.webp)
Chapter
10
Operating Instructions
CLV 490 Bar Code Scanner
10-64
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Appendix
¾
On the
AUTOFOCUS
P
ARAMETERS
tab, click the A
UTOFOCUS
O
PTIMIZATION
P
ARAMETERS
button.
The A
UTOFOCUS
O
PTIMIZATION
P
ARAMETERS
tab then opens (
).
¾
Set the following parameters:
– Delay of focus change
Timeout:
50 ms
Hysteresis:
50 mm (2 in)
– Distance Measurement:
active
Source of distance information
: internal
Smooth filter active:
active
Length:
3
(default setting)
¾
Close the A
UTOFOCUS
O
PTIMIZATION
P
ARAMETERS
tab.
Fig. 10-48: Parameterization example: "Autofocus Optimizations" tab