b
If necessary, use a water level to check that the components are parallel.
b
The alignment bracket makes it possible to rotate the sender and receiver around
the axis of the device and to align them accurately,
.
Mounting the safety light curtain without the alignment bracket
4 x
4 x
WS
13 mm
Scope of delivery
Required tools
Figure 5: Mounting the safety light curtain without the alignment bracket
b
Use wrench size 13 mm.
Figure 6: Mounting the safety light curtain without the alignment bracket: Step 1
1.
Using 6 to 8 revolutions, screw in the two M8 screws for mounting the lower end of
the explosion-proof enclosure. Make sure you leave enough space between the
screws and the mounting surface for the lower end of the explosion-proof enclo‐
sure.
3
MOUNTING
14
O P E R A T I N G I N S T R U C T I O N S | C4000 Fusion Ex
8022867/2019-03-04 | SICK
Subject to change without notice