![SICK C 4000 Series Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/sick/c-4000-series/c-4000-series_operating-instructions-manual_1264382037.webp)
Operating Instructions
Chapter
6
C 4000
Commissioning
8 009 221/16-11-00
©
SICK AG • Safety Systems • Germany • All rights reserved
37
6.3.3
Daily function checks of the protective device
The effectiveness of the protective device must be checked daily by a specialist or by au-
thorized personnel, using the proper test rod.
Note
Always align the test movements along the hazardous area to be protected, never along the
mounting position of the light curtain.
How to check the effectiveness and proper function of the safety light curtain:
>
Select the correct test rod depending on device resolution. If you operate the unit with
reduced resolution (display
r
on the receiver), select the test rod using the following
table:
WARNING
No operation while the green or yellow LED is lit during the test!
If the green or orange LED lights up
during the test
even for a short period, work must stop
at the machine. In this case the installation of the safety light curtain must be checked by
specialized personnel (see chapter 4).
>
Before
inserting the test rod, check that the green LED is lit if the internal restart inter-
lock is deactivated and that the yellow LED flashes (“Reset required”) If this is not the case,
make sure that this condition is reached. The test is otherwise meaningless.
>
Move the test rod slowly through the protective field to be tested, as shown in
in figure 28.
>
Then move the test rod along the edges of the protective field, as shown in
in
figure 28. This procedure allows you to test if the point-of-operation guard/reaching
behind protection is functioning properly (see 4.2 “Steps for mounting the device” on
page 25).
Note
In both tests, the receiver of the C 4000 must show the red LED only.
Fig. 28: Daily checks of the
protective device
Physical resolution
Reduction
Effective resolution
14 mm
1 beam
22 mm
2 beams
30 mm
3 beams
37 mm
20 mm
1 beam
30 mm
2 beams
40 mm
Tab. 12: Selecting the test rod
under reduced resolution
R
Q
Содержание C 4000 Series
Страница 1: ...O P E R A T I N G I N S T R U C T I O N S S a f e t y L i g h t C u r t a i n C 4 0 0 0 ...
Страница 2: ...Operating Instructions C 4000 2 SICK AG Safety Systems Germany All rights reserved 8 009 221 16 11 00 ...
Страница 3: ...Operating Instructions C 4000 8 009 221 16 11 00 SICK AG Safety Systems Germany All rights reserved 3 ...