6.4.1
Encoder parameters
Object 6000h – Operating Parameters
Table 76: Object 6000h
Object
Access
Data type
Designation
Data values
6000h
R/W
UINT-16
Operating Parameters
Table 77: Object 6000h – details
Bit
Designation
Description
Data values
15
Manufacturer-specific
-
14
RTSYNC mode
The encoder determines the position every 250
µs
1
. A Transmit PDO with a transmission type of
always “takes” the
last position value, which may already be 250 µs
old.
If the RT SYNC mode is active, then the formation
of the position is synchronized with the SYNC mes‐
sages from the master. This means the position
value is determined at exactly the point at which the
request for the Transmit PDO arrives.
0
Not active
1
Acive
13
Manufacturer-specific
-
12
Activation of new encoder functions
•
Access to object 1F80 hex NMT startup (self-
starting device) possible
•
Access to object 2022 hex (absolute diagnos‐
tic data stored permanently); Switching between
relative and absolute diagnostic data in object
2012 hex is no longer required
0
Not active
1
Active
11 ... 3
Reserved
-
2
Scaling
The bit enables scaling with objects 6001h and
6002h.
0
Not active
1
Active
1
Commissioning diagnostic control
1
Always active
0
Code sequence (cw, ccw)
The code sequence defines the direction of rota‐
tion, viewed on the shaft, in which the position
value increases.
•
Clockwise = increasing position value on clock‐
wise revolution of the shaft
•
Counterclockwise = increasing position value on
counterclockwise revolution of the shaft
0
cw
1
ccw
1
Additional latency time due to sensor-internal processes: 500 µs.
Object 6001h – Counts Per Revolution (CPR)
The resolution per revolution is configured using this parameter.
NOTE
The parameter is not used if the round axis functionality is activated.
6
OBJECT LIBRARY
58
O P E R A T I N G I N S T R U C T I O N S | AHS/AHM36 CANopen
AHS/AHM36 CANopen Inox
8016869/1EF3/2021-12-08 | SICK
Subject to change without notice