Object Sub‐
index
Access
Data type
Designation
Description
Data values
.1
R/W
UINT-8
6300.01h CAM State
Register, Channel 1
.2
R/W
UINT-8
6300.02h CAM State
Register, Channel 2
.3
R/W
UINT-16
2010.03h STW-1 –
Device Status Word,
S_STAT-C
.4
R/W
UINT-32
2017h Speed Value
32-Bit
6.3.5
Objects and their subindices that can be mapped
Table 74: Objects and their subindices that can be mapped
Object Sub‐
index
Length
[Bit]
Designation
Mapping values
Details see
1001h
8
Error Register
10010008h
6004h
32
Position Value
60040020h
6030h
.1
16
Speed Value
60300110h
6503h
16
Alarm Status
65030010h
6505h
16
Warning Status
65050010h
6300h
.1
.2
8
8
CAM State Register
Channel 1
Channel 2
63000108h
63000208h
2010h
.1
.2
.3
16
16
16
STW-1 – Device Status
Word
S_STAT-A
S_STAT-B
S_STAT-C
20100110h
20100210h
20100310h
2014h
32
Time Counter
20140020h
2015h
16
Temperature Value
20150010h
2016h
32
Position Value, Raw
20160020h
2017h
32
Speed Value 32-Bit
20170020h
2018h
.1
.2
16
16
Time Counter Signals
Time Counter MSec
Time Counter Sec
20180110h
20180210h
Changing the PDO mappings
NOTE
Parameter changes to the PDO mapping objects are only executed in the status Pre‐
operational.
How to change the content of the mapping objects:
6
OBJECT LIBRARY
56
O P E R A T I N G I N S T R U C T I O N S | AHS/AHM36 CANopen
AHS/AHM36 CANopen Inox
8016869/1EF3/2021-12-08 | SICK
Subject to change without notice