5.8.2
Scaling parameters
The scaling parameters are configured by the objects 6000h, 6001h and 6002h.
Figure 15: Objects 6000h, 6001h and 6002h in TwinCAT®
6000h – Operating Parameters
Using the object
6000h
the parameters
Support additional
Error Code
,
Scaling
and
Code sequence
are configured. The object is configured using
a bit sequence 16 bits wide.
Example:
•
Bit 0 = code sequence ccw = 1
•
Bit 2 = scaling on = 1
Table 32: Example for binary code
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Value
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
The binary value must be converted into a hexadecimal value and entered in the
configuration dialog box.
101b = 5h
Figure 16: Example for the parameterization of object 6000h
Scaling
This parameter makes it possible to scale the resolution per revolution and the total
resolution.
NOTE
Only if the parameter
Scaling
is configured to
1
are the values entered for the resolu‐
tion and total resolution applied.
Code sequence
The code sequence defines which direction of rotation increases the position value; the
direction of rotation is defined looking at the shaft.
•
clockwise (cw) = increasing position value on clockwise revolution of the shaft
•
counterclockwise (ccw) = increasing position value on counter clockwise revolution
of the shaft