Attribute ID
Function
Detailed descrip‐
tion
Acc
ess
Data type
Content/meaning
0xD3
Teach in 2-point
R/W UINT
1: CH1 2: CH2
0xDA
Reset
R/W UINT
3: Execute
0xDB
Return to start menu
R/W UINT
Write any value to return to start
menu
0xDC
Reset to factory settings
R/W UINT
3: Execute
7.8.4
Class 103 OD1 on AOD1
Table 39: Class services of class 103
Service code
Service
Description
0Eh
Get_Attribute_Single
Returns the values of an attribute
Table 40: Instance services of class 103
Service code
Service
Description
0Eh
Get_Attribute_Single
Returns the values of an attribute
10h
Set_Attribute_Single
Sets the value of an attribute
1
The available instance service depends on the type of access for the respective attribute.
Table 41: Class 103 OD1 on AOD1
Attribute ID
Function
Detailed descrip‐
tion
Acc
ess
Data type
Content/meaning
0x01
Output 1
R
BOOL
Output state of first output (0 = Off,
1 = On)
0x02
Output 2
R
BOOL
Output state of second output (0 =
Off, 1 = On)
0x03
Output 3 / Ext. input
R
BOOL
Output state of third output (0 = Off,
1 = On)
0x04
Error Status
R
BOOL
Error status (0 = No error, 1 = Error)
0x05
Measured value
R
UINT
Distance measurement
0x06
Teach request
R/W BOOL
Coding see Class 100 Attribute
0x07
Error Clear
R/W BOOL
Acknowledgment of error message
(when value changes from 00 to 01)
0x08
Product series
-
R
UINT
0x1301 (15 mm model)
-
0x1302 (35 mm model)
-
0x1303 (100 mm model)
b15–12 Manu‐
facturer
1: SICK
b11–8 Cate‐
gories
3: Displacement
b7–0 Family
1: OD1 15 mm
-
2: OD1 35 mm
-
3: OD1 100 mm
0x09
Product type
R
UINT
1: AOD1
0x0A
firmware version
R
UINT
0x0100
0x0C
Product version
R
UINT
0
0x0D
Vendor name
R
STRG
“SICK AG”
0x0E
Product name
R
STRG
Respective product type name
7
OPERATION
32
O P E R A T I N G I N S T R U C T I O N S | WI180C-EN
8024950/2019-11-04 | SICK
Subject to change without notice