Minimum
Typical
Maximum
Current consumption
30 mA
Light spot diameter
Near-infrared (NIR), invisible
Red light, visible
approx. 110 mm at a distance of 8 m
approx. 90 mm at a distance of 8 m
Test input for the sender
2)
Sender off
≤ 3 V
Sender on
≥ U
v
– 4 V
1)
The test input has a pull-up resistor to activate the sender (sender on) even when not connected. There‐
fore, an active-switched LOW signal is required to activate the cyclic test with test gap (sender off).
2)
The test input must not be operated when not connected.
Technical data for receiver
Table 11: Technical data for receiver
Minimum
Typical
Maximum
Current consumption (without load)
30 mA
Switching outputs
1)
Push-pull
Response time
2)
500 µs
Signal voltage HIGH
U
V
– 3.2 V
U
V
– 2.5 V
U
V
Signal voltage LOW
1 V
Output current I
A
100 mA
1)
Output signal switching device for controlling the downstream test device, no OSSD according to IEC
61496-1. Output short-circuit protected.
2)
Signal transit time with resistive load.
Operating data
Table 12: Operating data
System connection
M12, 4-pin
Ambient operating temperature
–40 °C … +60 °C
Air humidity (non-condensing)
15 % … 95 %
Storage temperature
–40 °C … +75 °C
Housing cross-section
20 mm × 42 mm, plus bracket,
Vibration resistance
1)
5 g, 10 Hz … 55 Hz (IEC 60068-2-6)
Shock resistance
2)
10 g, 16 ms (IEC 60068-2-27)
1)
Test conditions per axis: 1 octave/minute, amplitude: 0.35 mm, 20 sweeps.
2)
Test conditions per axis: 1000 shocks.
12
TECHNICAL DATA
40
O P E R A T I N G I N S T R U C T I O N S | L25
8024678/2020-01-24 | SICK
Subject to change without notice