Further topics
•
7.6.3
Monitoring cases
Overview
On the
Monitoring cases
page, you create different monitoring cases for the device.
For each monitoring case, you can use the fields defined on the
Fields
page or the
predefined cut-off behaviors to define the cut-off paths. You can use protective fields for
the safety cut-off path 1, and warning fields for the non-safety cut-off path 2.
You can also assign sleep mode to one monitoring case.
1
Settings for all monitoring cases
2
Settings for a single monitoring case
3
Input conditions for the monitoring case
4
Cut-off paths with the assigned field sets
5
Configured field sets
6
Areas for defined cut-off behavior
7
Remove field set from a monitoring case
Monitoring case table
You can create different monitoring cases in the monitoring case table. You have the
following options for each monitoring case:
CONFIGURATION
7
8025990/2021-03-03 | SICK
O P E R A T I N G I N S T R U C T I O N S | scanGrid2 CANopen
75