Aqua Cubic Multiplex
-
MAN0004 Rev. B 29.03.99
9/33
6 – INSTRUCTIONS FOR USE
6.1 –
Turning on
The appliance is turned on via the main switch
ON (I)
-
OFF (0)
situated on the front panel. This switch acts on both
supply cables
The supply voltage must be
24 Vac - 50 Hz
. (on demand
24 vac – 50 Hz.
)
Check the supply voltage using the adhesive labels situated on the cover of the connections.
6.2 –
Programming of the operative modalities
Before proceeding to the programming of
Aqua Cubic Multiplex
, it must be checked that the distributor cams are
positioned at the
stroke end
and that any
unused limit switch
entries on the terminal are closed with a connector
bridge. If this simple rule is not respected,
Aqua Cubic Multiplex
cannot enter into service and access to the keypad
will be limited after a few operations.
The programming will be carried out via the keypad on the front of the appliance.
Aqua Cubic Multiplex Plus
has the following operative modalities:
Tab. 4 – Table of the operative modalities
Code
Description
Rotation times
P P P 0
One single column
Regeneration in
4
phases with rotation time of
50
seconds
P P P 1
Three single columns
Regeneration in
4
phases with rotation time of
50
seconds
P P P 2
Two alternated single columns
Regeneration in
4
phases with rotation time of
50
seconds
P P P 4
One duplex column
Regeneration in
4
phases with rotation time of
25
seconds
P P P A
Two single columns in parallel
Regeneration in
4
phases with rotation time of
50
seconds
The selection takes place in accordance with the following sequence:
Tab. 5 – Selection of the operative modalities
Display
Operative state / Data visualised
PROGRAM
P 0 0 0
State of access to the selection of the operative modality
ENTER
P P P x
Visualisation of the current operative modality (x = 0, 1, 2, 4, A)
2 / +
P P P *
The key
2 / +
modifies the operative modality as per tab. 4