Siargo FS6122 Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 FS6122 User Manual

 

Integrated flow, pressure & temperature sensors

 

©2021  Siargo Ltd.

 

VB.0.1 

Sold in North America by:

Servoflo Corporation

75 Allen Street

Lexington, MA 02472

www.servoflo.com/[email protected]

781-862-9572

Содержание FS6122

Страница 1: ...ser Manual Integrated flow pressure temperature sensors 2021 Siargo Ltd VB 0 1 Sold in North America by Servoflo Corporation 75 Allen Street Lexington MA 02472 www servoflo com info servoflo com 781 8...

Страница 2: ...3100 De La Cruz Boulevard Suite 210 Santa Clara California 95054 USA Tel 1 408 969 0368 Email info siargo com Copyright 2021 and Liability Disclaimer Siargo Ltd and its subsidiaries reserve the right...

Страница 3: ...s product according to the specified parameters Only the trained or qualified personnel shall be allowed to perform product services Be cautious for electrical safety and even it operates at a low vol...

Страница 4: ...1 Product selection 11 6 2 Order contact and customer support 11 7 Product performance 12 7 1 Technical specifications 12 7 2 Pressure loss 13 7 3 Typical analog output 13 8 Technical notes for the pr...

Страница 5: ...and repair are also included The FS6122 sensors are manufactured with the company s proprietary MEMS micro electro mechanical systems sensing and package technology that offers primarily the mass flow...

Страница 6: ...actual order together with the power and data cable if the order is included as shown below Please check immediately for the integrity of the product and the power and data cable if any abnormality i...

Страница 7: ...the specified pressure full scale range If the pressure option is not selected this pin output is NULL 3 The flow rate analog outputs 0 5 4 5 Vdc corresponding with the specified flow full scale range...

Страница 8: ...tion and irrecoverable damage For the installation make sure to the leakage proof of the connections and all electrical precautions are applied Please make sure the electrical pins are properly engage...

Страница 9: ...Write 1 byte ensure no flow conditions 9DH 4 Write protection Write 4 bytes 0x53 0x49 0x41 0x52 One time effective 82H 12 Serial number Read ASCII 83H 5 Flow rate Read Int32 1000 SLPM CRC CRC Byte1 xO...

Страница 10: ...e write protection is disabled 2 The I2 C address is set to Bit 7 Bit 1 E g if the I2 C address is 1 0000 001x the write address will be 0x02 0000 0010 and the read address will be 0x03 0000 0011 3 Th...

Страница 11: ...ld not guarantee the response time for humidity the humidity value could take additional and unspecific time to reach the real value 6 2 Order contact and customer support The sales offices and the sa...

Страница 12: ...re 10 60 C Accuracy o 5 C Humidity 0 100 no condensation RH Accuracy 2 0 20 80 RH 5 0 other ranges Resolution 0 7 RH Response time 63 5 0 25 75 sec Gas compatibility Air O2 N2 Supply voltage 5 0 5 Vdc...

Страница 13: ...oss 7 3 Typical analog output The pressure loss shown in the graph is one directional The reverse direction will have an identical loss value The temperature and humidity data can only be accessed via...

Страница 14: ...ee environment for data accuracy Excessive contaminants such as vapors will lead to data deviation or even product malfunctions in severe cases For the medical applications it may be desired to have t...

Страница 15: ...comparison however in addition to the flow system setup conditions recommended by OIML R137 a stable flow system must be ensured This is because the current product is designed for a small pressure l...

Страница 16: ...llation etc other consequential or indirect damages of any kind To the extent permitted by law the exclusive remedy of the user or purchaser and the limit of Siargo s liability for any and all losses...

Страница 17: ...smantled for whatever reasons 4 Products that have been subject to working conditions beyond the technical specification as described by this manual or related datasheet published by the manufacturer...

Страница 18: ...Clara California 95054 USA Phone 01 408 969 0368 Email info Siargo com For orders please provide an accurate and full postal address Siargo will not ship to P O Boxes or via a third party Please cont...

Страница 19: ...e I2 C interface in serial For further information and purchase of the evaluation kit please contact the manufacturer or the sales representative Each converter has a fixed cable that can be directly...

Страница 20: ...A 13 I2 C communication protocol update 06 2020 VA 12 I2 C communication protocol update 10 2019 VA 11 Output pin assignment update 10 2018 VA 10 Add additional gauge pressure range 04 2018 VA 9 I2 C...