background image

 

SIABS S.r.l. – ITALY  

Phone +39 02 90384081 

E-mail       

[email protected]

 

via Del Lavoro, 7 

 

Fax     +39 02 9029538 

Web page  

www.siabs.com

    

20010 – Casorezzo (MILAN) 

 

Luminous  Infra-red  Gas Heaters 

 

 

 

 

MANUAL for INSTALLATION,  

RUNNING  and  MAINTENANCE  

 

 

 

 
 

Models:  4P, 6P, 8P, 10P, 12PR, 12P, 16P,  

4PB, 6PB, 8PB, 10PB, 12PRB, 12PB, 16PB, 

10+10P, 12+12P, 16+16P, 

10+10PB, 12+12PB, 16+16PB, 

10+10PS, 12+12PS, 16+16PS 

10+10PSB, 12+12PSB, 16+16PSB 

 

Version “DC and DCeco” 

 
 
 

Содержание 10+10P

Страница 1: ...b page www siabs com 20010 Casorezzo MILAN Luminous Infra red Gas Heaters MANUAL for INSTALLATION RUNNING and MAINTENANCE Models 4P 6P 8P 10P 12PR 12P 16P 4PB 6PB 8PB 10PB 12PRB 12PB 16PB 10 10P 12 12...

Страница 2: ...AS supply 12 connection to ELECTRIC feeding 13 SIT control unit wiring diagram ON OFF version 14 SIT control unit TWO STAGE version 15 and 16 SIT control unit wiring diagram TWO STAGE version 17 gas g...

Страница 3: ...g instructions by the Manufacturer incorrect installation can cause damage to people animals and things the Manufacturer doesn t accept any contractual and extra contractual liability in tort and cont...

Страница 4: ...se are subject to the conditions of the original warranty The guarantee is only the free supply on Ex Works basis of parts with manufacturing or workmanship defects The guarantee does not cover proble...

Страница 5: ...do not remove placed on the head of the appliance version DC or on the reflectors version DCeco Apparatus type A1 gas category II 2H3P Plate label example appliance 16 16PB version DC two stages G20...

Страница 6: ...m 3 h 0 69 0 91 1 53 1 75 1 81 2 12 3 43 3 50 4 24 6 70 Gas consumption MIN Sm3 h 0 52 0 69 1 15 1 31 1 35 1 59 2 95 2 62 3 18 5 90 Nozzle diameter mm 2 10 2 45 3 10 3 30 3 40 3 50 4 50 2 x 3 30 2 x 3...

Страница 7: ...sure a sufficient air change the flow of air needed can be calculated using the following equation UNI EN 13410 Vtot Qnb x L Vtot air change flow rate in m3 h Qnb total heating power installed in the...

Страница 8: ...different angled positions for the heater The following figures will show you how to install all types of appliances picture 1 Installation with chains DC picture 2 Installation at wall DC picture 1 I...

Страница 9: ...o be used in any case provide blocks with M8 screw minimum diameter e g anchor Fischer TA M in steel with M8 screw IMPORTANT appliances must be installed in horizontal position contact us in case of d...

Страница 10: ...stalled in horizontal position for appliances with angled position 15 60 the minimum height can be reduced roughly between a 5 15 angle and a 20 60 angle Quotes relate to installation with ambient tem...

Страница 11: ...pecial attention also in cases of installing appliances above crane ways to prevent damage to motor and electric cables The MINIMUM distances are as follows MODEL MINIMUM distance mt between heater an...

Страница 12: ...this condition With lower pressure difficulties in start up may occur Once the connection is made in compliance with the rules in force in the country of installation a verify the sealing of hydrauli...

Страница 13: ...In any case use a cable with minimum section 3x1 5mm2 ON OFF version or 4x1 5mm2 TWO STAGE version The wiring diagrams are shown on page 14 ON OFF version and page 17 TWO STAGE version of this manual...

Страница 14: ...Manu_ENG_DC_DCeco_rev 0_04_2012 page 14 WIRING DIAGRAM SIT control unit ON OFF...

Страница 15: ...g you will find the data heat input pressure and gas flow rate referring to the appliances with TWO STAGE version in the tables at page 6 of this manual N B MINIMUM heating capacity feed L1 N MAXIMUM...

Страница 16: ...pressure regulator Act as shown in picture 2 on the CH10 screw for setting of the maximum pressure till you get the required pressure turn clockwise to increase and counter clockwise to decrease Take...

Страница 17: ...Manu_ENG_DC_DCeco_rev 0_04_2012 page 17 WIRING DIAGRAM SIT control unit TWO STAGE...

Страница 18: ...rner models 4P 6P 8P 10P 12P e 16P They are equipped with 1 gas valve and 1 flame control B_appliances with 2 burners models 10 10P 12 12P e 16 16P Appliances with 2 burners can be equipped with 2 gas...

Страница 19: ...side this range the start up between the 2 burners and safety of the units is NOT guaranteed IMPORTANT appliances with 2 burners and only 1 gas group gas valve and flame control are equipped with only...

Страница 20: ...into block after 30 seconds for re start it is necessary to remove tension for a period of not less than 20 seconds after that period of time the start up sequence can be repeated if the heater contin...

Страница 21: ...rical connections search for possible losses on the gas circuit and gas valve check of gas pressure at nozzle general control of all components of the appliance control of openings and ventilation sys...

Страница 22: ...f e from LPG G30 to G20 natural gas it is compulsory to change also the plate label with technical data placing a new label with the new data repeat checks listed at page 20 PUT IN OPERATION and FIRS...

Страница 23: ...ceramic plates D the heater doesn t turn D1 Interruption in the elctric plant D1 Verify voltage at connector of power suppy because no gas is getting D2 No tension D2 Replace the control unit D3 Sole...

Страница 24: ...or gas conversion nozzle plate label page 5 ____ ____ nozzle various ____ SIT gas valve SIGMA 840 for models ON OFF 2550000004 ____ SIT gas valve SIGMA 843 for models TWO STAGES 2550000005 ____ SIT fl...

Страница 25: ...e to appropriate separate collection centres of electric and electronic waste or return it to the dealer when purchasing a new device to be equivalent in terms of one to one The proper differentiated...

Страница 26: ...Manu_ENG_DC_DCeco_rev 0_04_2012 page 26 CE certificate...

Страница 27: ...Manu_ENG_DC_DCeco_rev 0_04_2012 page 27 DATE and STAMP OPERATION NOTES OPERATION NOTES DATE and STAMP DATE and STAMP OPERATION NOTES DATE and STAMP OPERATION NOTES...

Страница 28: ...o MILAN ITALY ___________________________________________________________________________ to contact us Phone 39 02 90384081 Fax 39 02 9029538 E mail commerciale siabs it Web page www siabs com Contin...