SIA SIA-24-L35-CR-TS-150113-HIEC Скачать руководство пользователя страница 24

Solar Injection Australia

Specialising in chemical injection pump technology for the oil and gas industry, Solar Injection 
is a leading design and manufacturing business focused on delivering innovative, quality 
solutions.

Our approach is to innovate rather than imitate. The SiA brand of high quality and highly 

efficient pumps includes solar-powered; pneumatic/gas; and AC chemical injection pumps that 
are suitable for a wide range of applications, including hazardous area, sour gas and where 

other specialist requirements are needed. Our timers, controllers and detection accessories 

give our customers unparalleled control of the pumps both onsite and remotely (via SCADA).

With our network of distributors, we design and deliver customised solutions throughout the 
world – emerging now as a leader in unconventional energy.

Innovation

Innovation rather than 
imitation.

Quality

Quality in everything we 
do and the materials we 

use.

Experience

Experience you can rely 

on with 30+ years in Oil 

& Gas.

Distribution

Distribution - providing 

local experience and 
expertise.

Solar Injection Australia

www.solarinjection.com.au

[email protected]

592 Tarragindi Rd, Salisbury, 

QLD 4107 Australia

+61 7 3277 8822

CONTACT US FOR FURTHER INFORMATION

SIA DISTRIBUTOR:

Содержание SIA-24-L35-CR-TS-150113-HIEC

Страница 1: ...MANUAL INSTALLATION OPERATION MAINTENANCE SiA CHEMICAL INJECTION PUMP...

Страница 2: ...ES THIS DRAWING CONTAINS CONFIDENTIAL INFORMATION AND IS COVERED BY COPRIGHT LAWS REPRODUCTION EITHER SIA 24 L35 CR TS 150113 HIEC GENERAL ARRANGEMENT F P DRAWN TO AS1100 1992 UNLESS NOTED OTHERWISE A...

Страница 3: ...085 24 150113 IEC THUBA CH 4015 BASEL II 2G 1 16 A 1 2 3 4 5 6 6 5 4 3 2 1 B C D E F F E D C B A NO MANUAL REVISIONS ALLOWED A3 592 Tarragindi Road Salisbury Qld 4107 Tel 61 7 3277 8822 SCALE STATUS S...

Страница 4: ...0 375 2 15 UHMWPE 40065 2 4 MAIN SEAL 0 375 1 16 Stainless Steel 40056 RETURN SPRING 1 17 A 1 2 3 4 5 6 B C D E F F E D C B A NO MANUAL REVISIONS ALLOWED A3 592 Tarragindi Road Salisbury Qld 4107 Tel...

Страница 5: ...n Environment 2 2 Installation Step by Step SECTION 3 PUMP OPERATION 3 0 Operating Pump With SiA Timer Controller 3 1 Chemical Injection Flow Rate Adjustment SECTION 4 MAINTENANCE 4 0 Routine Maintena...

Страница 6: ...rsized sealed bearings so as to eliminate all overhung loads This greatly increases the life of the gear motor s gearbox By applying a rotary force to the end of the crank shaft the force is transmitt...

Страница 7: ...his manual for part numbers specific to your pump Voltage Watts Ratio Gearbox Type Hazardous Area Certifications Standard 12 24 120 240 220 415 20 40 60 90 120 150 50 75 150 Spur N A Standard BLDC 12...

Страница 8: ...FUSE REQUIRED 12 Volt 24 Volt High Efficiency 150 100 IEC NA NA 7 5 amp 5 amp Standard 40 60 90 120 150 5 amp 10 amp 15 amp 20 amp 25 amp 2 5 amp 5 amp 7 5 amp 10 amp 12 5 amp For other wattage motors...

Страница 9: ...rd all plastic closures on the Liquid End and align pump connections as dictated by your overall system design 2 Connect the suction check valve to a gravity fed chemical source This pump requires a f...

Страница 10: ...the power is connected To avoid this fit an On Off isolating switch between the timer s Motor Terminals on the PTH and the motor s terminals Fuses It is very important that the correctly sized fuse is...

Страница 11: ...s at different times days of week On Time Sets the On Time in seconds used in Fixed Mode 2 1 60 Off Time Sets the Off Time in seconds used in Fixed Mode 10 1 60 Flow Rate Sets the desired flow rate in...

Страница 12: ...re the controller has power on and the display shows as per on the previous page 2 Depress the twice or until the display shows OPTIONS and then depress the Select button 3 Depress the or buttons unti...

Страница 13: ...f it was on OPERATION cont 1 Power On LCD DISPLAY When rotating indicates Controller is running Clock Indictaes operation Start Timer Depress Select button to quick start Controller from this screen B...

Страница 14: ...st effective robust capable of operating at more extreme ambients and has been found to use less energy per volume of chemical injected Solar Injection Australia manufactures a range of DC Timers plea...

Страница 15: ...n in any way they should be replaced immediately with new parts available from Solar Injection Australia or SiA Distributors 6 Place the Crank Shaft and Bearings or replacement Bearings into the Drive...

Страница 16: ...nd chemical compatibility is paramount Our standard plunger seal TS is a specially formulated PTFE and stainless steel compound that is energized with a Viton o ring which is compatible with most chem...

Страница 17: ...LDC Motor To inspect and or replace brushes on our Standard PMDC Gearmotor models please follow the steps below 1 Disconnect power to pump before any servicing takes place 2 Use large flat blade screw...

Страница 18: ...Check seal if swollen check chemical compatibility and replace Check selection and ensure discharge line is not blocked Check and replace fuse in DC supply If this condition repeats itself check the d...

Страница 19: ...Barium Chloride C C C B A A A A A Barium Sulfite B A A A A A A A Benzaldehyde B A A A A C C C Benzene A A A A A C B C C Benzene Sulfonic Acid lO C B B A A A A C C Benzoic Acid C B B A A A C A Benzoyl...

Страница 20: ...C C B A A A A Copper Fluoride C B B B A A Copper Nitrate C B A A A A A A A Copper Sulfate B A A A A A A A A Cottonseed Oil A A A A A A A A Creosols A A A A A C C C A Cyclohexane B A A A A C A C A Cyc...

Страница 21: ...A A A Magnesium Carbonate A A A A A A A A Magnesium Chloride C B B A A A C A Magnesium Nitrate A A A A A A A A Magnesium Sulfate B A A A A A A A MaleicAcid Dilute C B A A A A A C Melamine Resins C B B...

Страница 22: ...Sodium Acetate B A A A A C B C Sodium Aluminate B A A A A A B A A Sodium Bicarbonate B A A A A A A A A Sodium Bichromate B A A A A A A Sodium Bifluoride Slurry A A A C Sodium Bisulfate B A A A A A A...

Страница 23: ...Tetrachloride Dry A A A A A A B C Toluene A A A A A C B C C Tributyl Phosphate B A A A A C C C Trichloroethylene Dry A A A A A C A C Tricresyl Phosphate B A A A A C B C A Triethanolamine A A A A B C A...

Страница 24: ...e needed Our timers controllers and detection accessories give our customers unparalleled control of the pumps both onsite and remotely via SCADA With our network of distributors we design and deliver...