SI-TEX SVS-650
34
Operation
6.
Pulse
▶
[MENU] -> 6.
Pulse
This menu function chooses the Pulse length of the transducer output. Pulse lengths are
automatically selected based on the depth range. With the Pulse control the operator can select the
pulse length preferences. From 0.5X up to 1.5X, the short pulse lengths are used in shallow water
and give more detail, the longer pulse lengths are used in deeper water for better depth penetration.
(
☞
the default setting is M = 1X.)
7.
Output Power
▶
[MENU] -> 7.
Output Power
This menu function selects that output power from the SVS-650 to the installed transducer. The
default for the SVS-650 is for full power output of 600 watts RMS. When working in shallow water it
may be preferable to choose a lower output power level to help reduce screen clutter from excess
output signal level. The choices are off / L / M / H
(
☞
the default setting is H)