Page
All Rights Reserved Shyam Telecom Limited 27/36
Next Generation
Signal Enhancement
IV) Alarms (Figure 12)
Figure 12: Alarm Window (DL path alarms activated)
Observation Remarks
DL synthesizer fail
Failure of synthesizer in DL is indicated.
PA Off (Auto) DL
Indication draws the attention about the off
condition of PA in DL.
PA Off (Manual) DL
Indication draws the attention about the off
condition of PA in DL.
PA Power Low -DL
Indicates the PA power becoming lower than the
configured condition in DL.
PA Power High -DL
Indicates the PA power becoming higher than
the configured condition in DL.
PA Temperature
High-DL
Alarm indication draws that the temperature of
PA in DL has exceeded the limit.
RSSI Low-DL
Indication that the RSSI level has gone lower
than the pre-set limit in DL.
LNA-DL
Indicates the failure condition of LNA in DL.
System Temperature
High
Displays that the temperature of the overall
system has gone high.
Monitoring interval is 3 seconds i.e. after every 3 seconds data on the monitoring
window will be refreshed.