18
English
Power Limit 1
This item allows you to limit the long duration power limit. 100000 means 100W.
The choice: 0 ~ 4095875.
Power Limit 1 Time Window
This item allows you to select the MAX time for overriding the long duration
power limit. 0 means auto. The unit is second.
The choice: 0, 1, 2, 3, 4, 5, 6, 7, 8, 10, 12, 14, 16, 20, 24, 28, 32, 40, 48, 56,
64, 80, 96, 112, and 128.
Power Limit 2
This item allows you to limit the MAX power limit. 100000 means 100W.
The choice: 0 ~ 4095875.
XMP Configuration
This item allows you to select the DRAM timing parameters.
The choice: Default SPD, Custom profile, XMP profile 1, and XMP profile 2.
DRAM Frequency
This item allows user to adjust DRAM Frequency.
The choice: Auto, 1867, 2133.
CPU Core Voltage / CPU Graphics Voltage / DRAM Voltage / CPU System
Agent Voltage / VCCST Control / CPU VCCIO Voltage
These items allow you to adjust voltage setting for components.