4008 RV By-Pass Pump

 

By SHURflo

 

Installation & Maintenance Manual

Installation Preparation

The goal of installation is to provide a quiet, easy-
to-maintain installation with good flow and low 
backpressure.  This can be accomplished with 
the following guidelines:

• 

Mount on a 

solid surface

 in an 

accessible

location

 for strainer cleaning and pump main-

tenance.

• 

Use

flexible high-pressure hose

 on the pump 

inlet and outlet 

[such as SHURflo Kit 94-591-

00].

The pumps ports and strainer

should not

be connected to plastic or rigid pipe, or the 
pump's normal motion 

will

transmit through 

rigid plumbing  causing noise, and possibly 
loosening or cracking components.

• 

Pump must use an adequate 50-mesh

strainer

[such as SHURflo 255 series strainers].

• 

Use a minimum of 

1/2" [13mm] Inner Diame-

ter

 plumbing.  Smaller  ID plumbing will cause 

cavitation, high backpressure, low flow and 
noise.

• 

No need for an accumulator

 with by-pass pumps.

• 

Pump is designed for 

intermittent duty

 only: Do not use these pumps for running a Reverse-Osmosis [RO] Filtration 

System.  High pressure-continuous duty usage will shorten the life of the pump and is not covered under warranty.

• 

Wire Size is 16 GA 

MINIMUM

, 12GA is recommended---

See Wire Chart

 in Electrical Section for minimum sizing.

• 

Minimum power requirement is a 10 Amp circuit.

• 

Reduce restrictions on inlet and outlet.

  This includes small inner diameter shut-off valves, winterizing valves and 

elbows.

• 

If

 the RV has an 

Intellitec Pump Controller

, it must be rated at 10 or 15 amps; If the controller is rated at 7.5 Amps, a 

new controller or a high-amp relay must be used.

Mounting

• 

Mount the pump within 6 feet of the tank for best performance and pump life.  The pump will pull farther, but the farther it 
pulls the more work it does, increasing vibration and noise, and reducing the output and pump life.

• 

Mount pump in a space of at least 1 cubic foot for adequate ventilation to prevent overheating. 

• 

Pump may be mounted in any position.

• 

Mount pump for easy access for cleaning strainer, maintenance and service.

• 

Mount pump on a solid surface to prevent vibration and noise.

Electrical

• 

The pump works best on an individual filtered circuit, protected by the recom-
mended fuse or breaker specified on the label.

• 

A 15-Amp switch is recommended and should be on the positive lead.

• 

Wire Sizing:  Proper wire sizing is required for good pump operation.  If the 
wire is too small, low voltage will affect the pump performance and can create 
a fire hazard. 

SHUT OFF POWER TO THE PUMP WHEN LEAVING THE RV UNATTENDED.

Plumbing

Installation of a strainer is required to prevent debris from entering the pump.
For noise and vibration reduction we recommend at least 18 in. [.5

M

] of 1/2" [13mm] I.D. flexible high-pressure hose to 

both ports.  The pump ports and strainer 

should not

 be connected to plastic or rigid pipe.  This hose should be anchored 

where it meets the hard plumbing to reduce plumbing vibration.

SWIVEL FITTINGS

HIGH-PRESSURE

FLEXIBLE HOSE

SWITCH

POTABLE H20 INLET 

16GA [1,29mm] min.

GROUND

STRAINER

Typical Pump Installation 

Installation Guidelines

• 

Solid surface within 6 feet of tank

• Accessible location

• 

Minimize flow restrictions in the system

•  Strainer on pump inlet

• 

No accumulator needed

•  Properly sized wiring

• 

Flexible hose on inlet and outlet

•  Proper electrical protection

• 

Minimize plumbing elbows and valves

•  Properly sized plumbing

Minimum Wire Size for a 10% voltage drop on a 

12VDC, 10 Amp Circuit.  Length is the distance from 

the power source to pump and back to ground.

911-1008-D

Page 1 of  3

Feet

[Meters]

AWG

[mm²]

0 - 25

[0 - 7.6]

16

[1.3]

25 -50

[7.6 - 15.2]

14

[2.1]

50 - 70 [15.2 - 21.3]

12

[3.3]

70 -110 [21.3 - 33.5]

10

[5.3]

FUSE

CONNECTOR

SOLID SURFACE